![Sub-Zero Wolf ICBDF364C Service Manual Download Page 42](http://html.mh-extra.com/html/sub-zero/wolf-icbdf364c/wolf-icbdf364c_service-manual_1388401042.webp)
Page 42
International Dual Fuel (ICBDF) Series
International Dual Fuel (ICBDF) Series
Component Access & Removal
4-12
#814889- Revision A - July, 2010
Control Board, Relay Board, Motorized Door Latch
and Stand-By Power Board:
Using a small socket and driver, extract the screws that
secures the control board plate to the unit. Then, care-
fully pull the plate straight forward to the front of the unit
to gain access to the components.
NOTE
:
Before disconnecting any wires, make note of
their location. Make sure to reference the wiring dia-
gram when re-connecting any wires.
Now, extract the screws which secures the stand-by
power board to the control board plate and disconnect
the wiring. Then, remove the component (See
Figure
4-27
).
When re-installing the control board plate with compo-
nents back into the unit, be careful so the wiring to the
components don’t get snagged and pulled from their
location.
Figure 4-27. Component Removal from
Control Plate.
Stand-by power board