Page 44
International Dual Fuel (ICBDF) Series
International Dual Fuel (ICBDF) Series
Component Access & Removal
4-14
#814889- Revision A - July, 2010
Figure 4-33. Door Gasket Mounting.
Figure 4-34. Alignment between Bullnose & Door.
Figure 4-32. Use a 5/32” Allen Wrench to Adjust
Door.
Then, position door in hinge openings at a 30° angle from
vertical. Now, insert spring side hinge into hinge pocket.
Next, lower door to fully opened position and remove
hinge pin. Reinstall plate and screw over hinge opening.
Then, open and close door to insure its properly installed.
NOTE
:
On units with a new style single hinge retainer
plate (See
Figure 4-31
), you will need to install the single
hinge retainer onto the hinge claw prior to installing door.
Hinge
Retainer
Plate
Hinge
Pin
O
ld
S
tyle
Ne
w
S
tyle
Figure 4-31. Old style and New Style Hinge
Retainer.
Failure to screw in the bottom screw will lead to
future failure. The hole must be drilled and used to
secure the bracket.
NOTE
:
If replacing old style hinge retainer with new style
(See
Figure 4-31
), you will be required to drill a 9/64”
hole for the lower screw once door is installed and prior to
installing skirt.
For 48-inch and 60-inch units, complete this procedure for
both the left and right oven doors.
Door Adjustments
To adjust doors for height use a 5/32” allen wrench to turn
the allen screw for the hinge pocket. This will raise or
lower the oven door to the desired height allowing for
proper alignment between the bull nose and the top of the
oven door. Do this procedure for each side of the oven
door until the desired alignment is obtained (See
Figures
4-32
and
4-34
).
Door Gasket Removal
First, open the oven door. Now, locate the small clips
attached to the underside of the gasket and gently pull
the clips from the mounting holes. Next, pull the ends of
the gasket out from the bottom of the door liner and
remove (See
Figure 3-33
).
NOTE
:
On units starting with serial #16000000 the gas-
ket will be mounted to the front collar of the cavity.
Removal procedure is the same.