Malfunctions
124
Sherpa 120, 140 | 06.19
8.1.3
List of malfunctions, weighing device
NOTE
It is absolutely imperative to observe the enclosed operating instructions for the weighing device.
Malfunction
Cause
Remedy
Device cannot be switched on
No power supply
Check connecting cable
Switch power supply on, check
power supply battery
Wrong polarity
Check polarity connecting cable
(the devices are equipped with an
automatic fuse)
Device displays bars (top or
bottom)
Device
Pull the terminal box plug out of
the weighing computer and watch
display.
If the bars disappear, the weighing
computer functions properly.
Terminal box
Pull out the plugs of all weighing
rods, the terminal box being
plugged into the weighing
computer. Watch display. If the
bars disappear, the display
functions properly.
Weighing rods
Always plug only one weighing rod
at a time into the terminal box or
directly into the weighing
computer. If the bars disappear,
the respective weighing rod
functions properly.
Weighed value varies
Device
See malfunction description:
"Device displays bars"
Terminal box
Weighing rods
Scale displays wrong weighed
value
Weighing rods not properly
installed
Always plug only one weighing rod
at a time into the terminal box or
directly into the weighing
computer.
The displayed value must
increase when load is applied.
Always test all rods.
Weighing system misadjusted
Readjust scale, see enclosed
operating instructions
"Recalibration".
Device displays ERROR
Internal error
Send device in for repair.
Tab. 9: List of malfunctions, weighing device