21
866-795-1586 • WWW.STONEAGETOOLS.COM
CONTROL BOX SET-UP
OPERATION
REAR VIEW
SPEED / FLOW CONTROLS
CONTROL PANEL REMOTE BOX
+ -
+ -
DUMP CONTROL FITTING
INSTALL 1/4 IN. (6.35 MM) O.D. NYLON
TUBING (NOT INCLUDED) HERE
PNEUMATIC DUMP CONTROL FITTING AND LINE
A
DUMP CONTROL
is located on the Control Box panel and can be set up to control an air actuated dump valve. To utilize the toggle, the
end user will need to install 1/4 in. (6.35 mm) O.D. nylon tubing (not included) between the
DUMP CONTROL FITTING
and the pneumatic
dump valve.
(NOT INCLUDED)
CONTROL PANEL OPERATION
The Control Box consists of a base unit with a tethered Remote Box to allow the operator to easily move around if desired. There are two
levers on the Remote Box:
DUMP
and
HOSE FEED
. The levers are spring loaded to return to the center,
OFF
position.
The
DUMP
lever, when pushed forward, provides air to the ¼” push-connect fitting that is intended to supply air to a pneumatic dump valve to
divert high-pressure water to the tool.
When the
HOSE FEED
lever is pushed forward, it drives the hose forward into the pipe. When the
HOSE FEED
lever is pulled backward, it
retracts the hose from the pipe.
Forward and Reverse
HOSE FEED SPEED
can be adjusted independently using the brass colored flow control valves on the base of the
control box. The Forward and Reverse directions are labeled. Rotate the flow controls in the clockwise direction to increase the speed and
counterclockwise to slow the speed. Slow speeds are required to go forward through bends. Faster speeds are acceptable during retraction.