5
Maintenance
Battery maintenance
Battery maintenance
DANGER
Incorrect handling or incorrect use of batteries and
chargers can cause serious damage. This can also
lead to serious hazards for the operator.
For each type of battery, the instructions provided
by the battery manufacturer regarding proper use,
care and maintenance, as well as the possible ha-
zards for the operator, must be followed precisely.
Lead-acid batteries, gel batteries and lithium-
ion batteries are currently used.
NOTE
•
Battery maintenance is not part of the
regular maintenance
•
Battery maintenance must be carried out
according to the information provided by the
relevant battery manufacturer
•
If the battery male connector is disconnec-
ted while a consumer is switched on, the
contacts can combust
Lead-acid batteries
Lead-acid batteries use liquid acid. The acid
can be easily accessed and can therefore be
dangerous.
DANGER
The electrolyte (battery acid) is toxic and corrosive
on contact. For newly charged batteries in particu-
lar, be aware of the risk of explosion in the area of
the battery where gas may be released.
When handling battery acid, the specified safety
measures must be observed.
Gel batteries
Gel batteries are a particular type of lead-acid
battery. The usage instructions and handling
instructions from the respective manufacturer
must be observed.
Li-ion batteries
To ensure safe operation, industrial trucks
that are powered by Li-ion batteries must be
equipped with a battery management system.
The operators of such industrial trucks must be
instructed in the operation of Li-ion batteries
and the charging systems for these batteries.
Battery maintenance
The battery is the energy source for the
industrial truck. It must therefore be handled
carefully!
General daily maintenance tasks
Keep the battery clean and dry.
Charge the battery regularly.
Avoid deep discharge.
Visually check the insulation on the cable
connections and battery female connector.
Check the condition of the battery connection
assembly and check that it is working cor-
rectly.
Additional maintenance work for lead-acid
batteries
Check the electrolyte level. If necessary, top
up with demineralised water.
Spilt electrolyte must be siphoned off from the
battery tray using a siphon. Rinse the tray if
necessary.
.
90
5212 804 3001 EN - 02/2017
Summary of Contents for EK-X10
Page 1: ...Original instructions High level order picker EK X10 2101 5212 804 3001 EN 02 2017 ...
Page 2: ......
Page 7: ...1 Foreword ...
Page 14: ...1 Foreword Operator form of address 8 5212 804 3001 EN 02 2017 ...
Page 15: ...2 Safety ...
Page 25: ...Safety 2 Application area 5212 804 3001 EN 02 2017 19 ...
Page 30: ...2 Safety Personal protective equipment 24 5212 804 3001 EN 02 2017 ...
Page 31: ...3 Overview ...
Page 46: ...3 Overview View into the control compartment 40 5212 804 3001 EN 02 2017 ...
Page 47: ...4 Operation ...
Page 85: ...5 Maintenance ...
Page 97: ...6 Technical data ...
Page 100: ...6 Technical data Driving speeds 94 5212 804 3001 EN 02 2017 ...
Page 101: ...7 Special equipment ...
Page 116: ...7 Special equipment Tilt barrier 110 5212 804 3001 EN 02 2017 ...
Page 122: ......
Page 123: ......