5
Maintenance
Service plan
Regular servicing at least every 12 months or after 2000 operating hours
At least once a year:
Regular testing according to the manufacturer's specifications
The regular testing must be performed by a specialist.
Observe additional national regulations for your country.
Check the condition, lubrication and voltage of the auxiliary lift load chains, and check for wear,
elongation and damage.
Determine the degree of wear of the main lift load chains (maximum permissible wear is 2%)
Determine the degree of wear of the auxiliary lift load chains (maximum permissible wear is 3%)
Final tasks
Test drive: check all functions and special functions according to the order.
Attach the service adhesive label
.