SB-7-632 Page 20
RECOMMENDED LUBRICANT
AEON PD Synthetic Blower Lubricant is recommended. Refer to FIGURE 3-3, for AEON PD, AEON PD-FG
(Food Grade) and AEON PD-XD (Extreme Duty) part numbers. Order AEON PD from your Gardner Denver
Distributor or call Gardner Denver directly.
Convenient
Package Sizes
AEON PD
Part No.
AEON PD-FG
Part No.
AEON PD-XD
Part No.
1 quart
28G23
28H97
28G46
Case
12 quarts
28G24
28H98
28G47
1 gallon
28G40
28H333
28G42
Case
6 gallons
28G41
28H334
28G43
5 gallon pail
28G25
28H99
28G44
55 gallon drum
28G28
28H100
28G45
FIGURE 3-3 – AEON PD SYNTHETIC LUBRICANT
AEON PD is formulated especially for positive displacement blower service to provide maximum blower protection
at any temperature. One fill of AEON PD will last a minimum of 4 times longer than a premium mineral oil. Refer
to FIGURE 3-4.
Ambient Temperatures
Less than 10° F
10°F to 32°F
32°F to 90°F
Greater than
90°F
Blower
Discharge
Temperature
Less than 32°F
AEON PD
AEON PD-FG
AEON PD
AEON PD-FG
32° F to 100° F
AEON PD
AEON PD-FG
AEON PD
AEON PD-FG
AEON PD
AEON PD-FG
100° F to 225°F
AEON PD
AEON PD-FG
AEON PD
AEON PD-FG
AEON PD
AEON PD-FG
AEON PD
AEON PD-FG
225° F to 300° F
AEON PD
AEON PD-FG
AEON PD
AEON PD-FG
AEON PD
AEON PD-FG
AEON PD XD
Greater than 300°F
AEON PD XD
AEON PD XD
FIGURE 3-4 – SYNTHETIC LUBRICANT CHART
Summary of Contents for TANVAC HDV3000
Page 2: ...1300 998 784 STGGLOBAL NET OPERATORS MANUAL TANVAC HDV3000 Sec on 1 ...
Page 11: ...8 4 COMPONENT IDENTIFICATION Engine Control Panel Control Panel ...
Page 14: ...11 Water System Water pump Switch Water Pump ...
Page 15: ...12 Water Strainer Hose Reel ...
Page 16: ...13 Water Tank Drain Valve Lever Vacuum System Dump valve Suction Valve ...
Page 17: ...14 Blower Vacuum ...
Page 19: ...16 Primary Shutoff Assembly Collection Tank Interior Bag House Lid ...
Page 20: ...17 Bag House Drain Valve Tools Water Gun ...
Page 34: ...31 20 3000lt ELECTRIC CONTROL BOX CIRCUIT DIAGRAM 1 ...
Page 35: ...32 21 3000lt ELECTRIC CONTROL BOX CIRCUIT DIAGRAM 2 ...
Page 36: ...33 22 3000lt VACUUM UNIT BOTTOM RAIL ASSEMBLE ...
Page 37: ...1300 998 784 STGGLOBAL NET OPERATORS MANUAL Cat 2 2 Opera on Manual Sec on 2 ...
Page 137: ... Table 32 contd 100 SEBU8312 03 Reference Information Section Maintenance Log ...
Page 141: ......
Page 144: ...1300 998 784 STGGLOBAL NET OPERATORS MANUAL Comet Manual Sec on 3 ...
Page 161: ...1300 998 784 STGGLOBAL NET OPERATORS MANUAL Sutorbilt R Series Sec on 4 ...
Page 200: ...SB 7 632 Page 39 SECTION 8 PARTS LIST ...
Page 202: ...SB 7 632 Page 41 ...
Page 204: ...SB 7 632 Page 43 301GAE810 A Ref Drawing ...
Page 206: ...SB 7 632 Page 45 ...
Page 208: ...SB 7 632 Page 47 ...
Page 210: ...SB 7 632 Page 49 303GAE810 A Ref Drawing ...
Page 212: ...SB 7 632 Page 51 ...
Page 214: ...SB 7 632 Page 53 ...
Page 216: ...SB 7 632 Page 55 300GAE810 A Ref Drawing ...
Page 218: ...SB 7 632 Page 57 ...
Page 220: ...SB 7 632 Page 59 ...
Page 222: ...SB 7 632 Page 61 302GAA810 A Ref Drawing ...
Page 224: ...SB 7 623 Page 63 ...
Page 226: ...1300 998 784 STGGLOBAL NET OPERATORS MANUAL Sutorbilt P Series Sec on 5 ...
Page 245: ...SB 7 622 Page 12 1 PIPE STEEL 2 SCH 80 2 MED CARBON STEEL 1 2 FIGURE 9 GEAR DRIVER SK2150 ...
Page 258: ...SB 7 622 Page 25 SECTION 8 PARTS LIST 300GAF810 B Ref Drawing ...
Page 260: ...SB 7 622 Page 27 300GAG810 A Ref Drawing ...
Page 262: ...SB 7 622 Page 29 300GAH810 A Ref Drawing ...
Page 265: ......
Page 266: ...1300 998 784 STGGLOBAL NET OPERATORS MANUAL Lofa Manual Sec on 6 ...
Page 294: ...1300 998 784 STGGLOBAL NET OPERATORS MANUAL Excava on Hydro SWMS Sec on 7 ...
Page 314: ...1300 998 784 STGGLOBAL NET OPERATORS MANUAL Pressure Cleaner Water SWMS Sec on 8 ...