SB-7-632 Page 22
SECTION 4
OPERATION
Future operating problems can be avoided if proper precautions are observed when the equipment is first put into
service.
Before starting under power, the blower should be turned over by hand to make certain there is no binding or
internal contact.
Each size blower has limits on pressure differential, running speed and discharge temperature which must not be
exceeded. These limits are shown in “Maximum Operating Limitations”, FIGURE 4-1, below.
Operating beyond the specified operating limitations will result in damage to the unit.
It is important that the pressures and temperatures are measured directly at the ports of the blower to avoid error
that may be caused by intervening pipe runs, fittings, etc.
Relief valves must be used to protect against excessive pressure or vacuum conditions. These valves should be
tested at initial startup to be sure they are adjusted to relieve at or below the maximum pressure differential rating
of the blower.
NOTICE
Relief valves should be placed as close as possible to the blower inlet or discharge.
In some instances, pressure may be relieved at a lower point than the blower maximum in order to protect the
motor or the equipment served by the blower.
Discharge temperature switches are recommended to protect against excessive inlet restriction or inlet
temperatures. Check valves in the discharge line on pressure blowers and in the inlet line on vacuum blowers are
recommended to protect the blower from motoring backwards when shut down under load.
LIMITATIONS
For information regarding limitations, refer to FIGURE 4-1, below.
MAXIMUM / MINIMUM OPERATING LIMITATIONS
SIZE
MAX.
RPM
MIN.
RPM
VERT.
MIN
RPM
HORIZ.
MAX.
PRESSURE
PSI
MAX
VAC
IN HG
MAX.
TEMPERATURE
RISE ° F
MAX.
DISCHARGE
TEMPERATURE ° F
3LR
3600
1528
1091
7
14
160
260
3MR
3600
1528
1091
12
15
180
280
3HR
3600
1528
1091
15
16
220
320
4LR
3600
1337
955
7
14
160
260
4MR
3600
1337
955
10
16
185
285
4HR
3600
1337
955
15
16
210
310
5LR
2850
1070
764
7
14
160
260
5MR
2850
1070
764
13
16
180
280
5HR
2850
1070
764
15
16
200
300
DO NOT EXCEED THESE LIMITS
NOTICE
Blower speed, line losses, elevation, and increased inlet temperatures will affect the maximum
operating limitations. The minimum RPM for the blowers is based on lubrication only. The blowers
may only be operated down to the minimum RPM, when the temperature rise and discharge
temperature are below the maximum limitations as shown.
FIGURE 4-1 – MAXIMUM / MINIMUM OPERATING LIMITATIONS
Summary of Contents for TANVAC HDV3000
Page 2: ...1300 998 784 STGGLOBAL NET OPERATORS MANUAL TANVAC HDV3000 Sec on 1 ...
Page 11: ...8 4 COMPONENT IDENTIFICATION Engine Control Panel Control Panel ...
Page 14: ...11 Water System Water pump Switch Water Pump ...
Page 15: ...12 Water Strainer Hose Reel ...
Page 16: ...13 Water Tank Drain Valve Lever Vacuum System Dump valve Suction Valve ...
Page 17: ...14 Blower Vacuum ...
Page 19: ...16 Primary Shutoff Assembly Collection Tank Interior Bag House Lid ...
Page 20: ...17 Bag House Drain Valve Tools Water Gun ...
Page 34: ...31 20 3000lt ELECTRIC CONTROL BOX CIRCUIT DIAGRAM 1 ...
Page 35: ...32 21 3000lt ELECTRIC CONTROL BOX CIRCUIT DIAGRAM 2 ...
Page 36: ...33 22 3000lt VACUUM UNIT BOTTOM RAIL ASSEMBLE ...
Page 37: ...1300 998 784 STGGLOBAL NET OPERATORS MANUAL Cat 2 2 Opera on Manual Sec on 2 ...
Page 137: ... Table 32 contd 100 SEBU8312 03 Reference Information Section Maintenance Log ...
Page 141: ......
Page 144: ...1300 998 784 STGGLOBAL NET OPERATORS MANUAL Comet Manual Sec on 3 ...
Page 161: ...1300 998 784 STGGLOBAL NET OPERATORS MANUAL Sutorbilt R Series Sec on 4 ...
Page 200: ...SB 7 632 Page 39 SECTION 8 PARTS LIST ...
Page 202: ...SB 7 632 Page 41 ...
Page 204: ...SB 7 632 Page 43 301GAE810 A Ref Drawing ...
Page 206: ...SB 7 632 Page 45 ...
Page 208: ...SB 7 632 Page 47 ...
Page 210: ...SB 7 632 Page 49 303GAE810 A Ref Drawing ...
Page 212: ...SB 7 632 Page 51 ...
Page 214: ...SB 7 632 Page 53 ...
Page 216: ...SB 7 632 Page 55 300GAE810 A Ref Drawing ...
Page 218: ...SB 7 632 Page 57 ...
Page 220: ...SB 7 632 Page 59 ...
Page 222: ...SB 7 632 Page 61 302GAA810 A Ref Drawing ...
Page 224: ...SB 7 623 Page 63 ...
Page 226: ...1300 998 784 STGGLOBAL NET OPERATORS MANUAL Sutorbilt P Series Sec on 5 ...
Page 245: ...SB 7 622 Page 12 1 PIPE STEEL 2 SCH 80 2 MED CARBON STEEL 1 2 FIGURE 9 GEAR DRIVER SK2150 ...
Page 258: ...SB 7 622 Page 25 SECTION 8 PARTS LIST 300GAF810 B Ref Drawing ...
Page 260: ...SB 7 622 Page 27 300GAG810 A Ref Drawing ...
Page 262: ...SB 7 622 Page 29 300GAH810 A Ref Drawing ...
Page 265: ......
Page 266: ...1300 998 784 STGGLOBAL NET OPERATORS MANUAL Lofa Manual Sec on 6 ...
Page 294: ...1300 998 784 STGGLOBAL NET OPERATORS MANUAL Excava on Hydro SWMS Sec on 7 ...
Page 314: ...1300 998 784 STGGLOBAL NET OPERATORS MANUAL Pressure Cleaner Water SWMS Sec on 8 ...