128
NOTE:
STEYR MOTORS GmbH reserves the right to publish the latest Version
of the Limited Engine Warranty Conditions under following link to
STEYR MOTORS GmbH Homepage:
http://www.steyr-motors.com/download/general-terms/
.
Edition 15.06.2016
High Output (HO)
. This power rating is intended for intermittent use in variable load applications where full
power is limited to one (1) hours out of every eight (8) hours of operation. Reduced power operations must be
at or below cruise speed (rpm). Cruise speed (rpm) is 300 rpm below the engine rated speed (rpm). Also, the
defined propped speed range must be met and is specified in table propped speed range (Operator Manual,
chapter Propeller selection) for each engine model. This rating (ISO3046 Fuel Stop Power Rating) is for ap-
plication operating less than 300 hours per year.
Intermittent Rating (INT)
. This power rating is intended for intermittent use in variable load applications where
full power is limited to two (2) hours out of every eight (8) hours of operation. Reduced power operations
must be at or below cruise speed (rpm). Cruise speed (rpm) is 200 rpm below the engine rated speed (rpm).
Also, the defined propped speed range must be met and is specified in table propped speed range (Operator
Manual, chapter Propeller selection) for each engine model. This rating (ISO3046 Fuel Stop Power Rating) is
for application operating less than 1,500 hours per year.
Medium Continuous Rating (MCD)
. This power rating is intended for intermittent use in variable load ap-
plications where full power is limited to three (3) hours out of every twelve (12) hours of operation. Reduced
power operations must be at or below cruise speed (rpm). Cruise speed (rpm) is 400 rpm below the engine
rated speed (rpm). Also, the defined propped speed range must be met and is specified in table propped speed
range (Operator Manual, chapter Propeller selection) for each engine model. This rating (ISO3046 Fuel Stop
Power Rating) is for application operating less than 3,000 hours per year.
STEYR MOTORS’ duty of performance under this Warranty is expressly conditioned upon the purchaser’s mainte-
nance of the following documentation and records which must be made available to STEYR MOTORS in the event
that warranty service is required:
• You are responsible for keeping complete and accurate records of all service performed on the engines
and for maintaining a log of all regularly scheduled maintenance in the Owner Service Log included in
your Operations, Maintenance and Warranty Manual.
• You are responsible for assuring that at all times the engine hour meter on your Steyr engines is in
good working order and in a condition that accurately reflects the total hours that the engines have been
operated.
• You are responsible for keeping copies of the completed Warranty Registration Approval
Summary of Contents for MO114K33
Page 2: ...This Page is intentionaly blank ...
Page 5: ...5 This page is intentionaly blank ...
Page 6: ...6 SAFETY PRECAUTIONS Safety Precautions 7 Introduction 7 ...
Page 21: ...21 This page is intentionaly blank ...
Page 49: ...49 This Page is intentionaly blank ...
Page 91: ...91 Wiring diagram MO 12 V 4 cyl from engine s n 482330250 ...
Page 92: ...92 Wiring diagram MO 24 V 4 cyl from engine s n 482330250 ...
Page 93: ...93 Wiring diagram MO 12 V 2 pol 4 cyl from engine s n 482330250 ...
Page 94: ...94 Wiring diagram MO 24 V 2 pol 4 cyl from engine s n 482330250 ...
Page 95: ...95 Wiring diagram MO E Box external 4 cyl from engine s n 482330250 ...
Page 96: ...96 Wiring diagram MO E Box external 2 pol 4 cyl from engine s n 482330250 ...
Page 101: ...101 Wiring diagram SE E Box 12V 6 cyl ...
Page 102: ...102 SE Series Wiring diagram SE E Box 24V 6 cyl ...
Page 103: ...103 SE Series Wiring diagram external SE E Box 6 cyl ...
Page 104: ...104 Wiring diagram SE E Box 12 V 4 cyl ...
Page 105: ...105 Wiring diagram external SE E Box 12 V 4 cyl ...
Page 106: ...106 Wiring diagram Instument CAN Panel 12 24V ...
Page 107: ...107 Wiring diagram Instument CAN Panel Solas 12 24V ...