82
Principle service code list "SE" engines
NOTE:
Some codes may not apply due to different application!
DTC List / Error Code List - SE Engines V50000.11 Version 4
Dec. Hex.
ABBREV.
INVOLVED DEVICE
POSSIBLE CAUSE
Variable
Limits
70
46
VTGHBRIDGE_E-FER
Turbocharger output
control
functional error on ECU-
H-Bridge
71
47
VTGHBRIDGE_E-MIN
Turbocharger output
control
signal voltage too low,
possible short circuit to
ground (X25)
72
48
VTGHBRIDGE_E-MAX Turbocharger output
control
signal voltage too high,
possible short circuit to
battery (X25)
263 107 BARO_FP_E-MIN
Barometric Pressure
Sensor
signal voltage too low,
possible short circuit to
ground
AdcCountBARO_
u16
20 cnts 0,098 V
264 108 BARO_FP_E-MAX
Barometric Pressure
Sensor
signal voltage too high,
possible short circuit to
battery
1000 cnts 4,888 V
274 112 ACT_E-MIN
Air Charge Tempera-
ture Sensor
signal voltage too low,
possible short circuit to
ground
AdcCountACT_
u16
50 cnts 0,244 V
275 113 ACT_E-MAX
Air Charge Tempera-
ture Sensor
signal voltage too high,
possible short circuit to
battery (B7)
1007 cnts 4,922 V
279 117 ECT_E-MIN
Engine Coolant Tem-
perature Sensor
signal voltage too low,
possible short circuit to
ground
AdcCountECT_
u16
22 cnts 0,108 V
280 118 ECT_E-MAX
Engine Coolant Tem-
perature Sensor
signal voltage too high,
possible short circuit to
battery (B6)
1000 cnts 4,888 V
288 120 PED_E-NPL
Potentiometer accel-
erator 1 & 2
Possibly wrong pedal
used (B9)
PED 1 + 2
≠ 5 V
290 122 PED1_E-MIN
Potentiometer accel-
erator 1
signal voltage too low,
possible short circuit to
ground
AdcCountPED1_
u16
20 cnts 0,098 V
291 123 PED1_E-MAX
Potentiometer accel-
erator 1
signal voltage too high,
possible short circuit to
battery (B9)
950 cnts 4,643 V
374 176 FUEL_DENSITY_E-NPL Fuel density sensor
Fuel Density value out of
range
> 1160 kg/
m³ or <
480 kg/m³
375 177 FUEL_DENSITY_E-FER Fuel density sensor
Timeout of fuel density
sensor - check connec-
tion and sensor
no signal
for 90s
395 18B PF20_RANGE_E-FER
PF20 - Fuel Pressure
Sensor
fuel pressure is below the
limit
< 2 bar for
10s
396 18C PF20_E-MIN
PF20 - Fuel Pressure
Sensor
signal voltage too low,
possible short circuit to
ground
AdcCountPF20_
u16
20 cnts 0,098 V
397 18D PF20_E-MAX
PF20 - Fuel Pressure
Sensor
signal voltage too high,
possible short circuit to
battery (B10)
1000,5
cnts
4,890 V
544 220 REM_PAD_E-SIG
Remote Pedal
time out of can message
received from remote ac-
celerator pedal
Summary of Contents for MO114K33
Page 2: ...This Page is intentionaly blank ...
Page 5: ...5 This page is intentionaly blank ...
Page 6: ...6 SAFETY PRECAUTIONS Safety Precautions 7 Introduction 7 ...
Page 21: ...21 This page is intentionaly blank ...
Page 49: ...49 This Page is intentionaly blank ...
Page 91: ...91 Wiring diagram MO 12 V 4 cyl from engine s n 482330250 ...
Page 92: ...92 Wiring diagram MO 24 V 4 cyl from engine s n 482330250 ...
Page 93: ...93 Wiring diagram MO 12 V 2 pol 4 cyl from engine s n 482330250 ...
Page 94: ...94 Wiring diagram MO 24 V 2 pol 4 cyl from engine s n 482330250 ...
Page 95: ...95 Wiring diagram MO E Box external 4 cyl from engine s n 482330250 ...
Page 96: ...96 Wiring diagram MO E Box external 2 pol 4 cyl from engine s n 482330250 ...
Page 101: ...101 Wiring diagram SE E Box 12V 6 cyl ...
Page 102: ...102 SE Series Wiring diagram SE E Box 24V 6 cyl ...
Page 103: ...103 SE Series Wiring diagram external SE E Box 6 cyl ...
Page 104: ...104 Wiring diagram SE E Box 12 V 4 cyl ...
Page 105: ...105 Wiring diagram external SE E Box 12 V 4 cyl ...
Page 106: ...106 Wiring diagram Instument CAN Panel 12 24V ...
Page 107: ...107 Wiring diagram Instument CAN Panel Solas 12 24V ...