IFBD-HE0708 BE07 User’s Manual
3-25
3.1.8.3.
F/W Update
Log in to this product using FTP to update the NIC firmware (F/W) by uploading the version upgrade binary data to the \firmware\
directory.
When uploading F/W data, the FTP server calculates the CRC value of the F/W data and checks that it has
been transferred correctly. If the firmware is not correctly transferred, cancel the upload.
When all data has been confirmed to be correctly received, start writing to the Flash ROM. If writing to the
Flash ROM ends normally, the printer will automatically be reset.
Writing takes several minutes. Absolutely never turn off the power or apply a reset prior to final reset being
applied. If terminated partway, the Flash ROM data will be damanged, and later it may not start up.
The following describes the procedures to update the F/W of this product using FTP.
For Windows, start the command prompt, then following the directions below. For UNIX/Linux, do the same opera-
tions on the shell execution screen.
(Assumed Conditions) Printer IP address = 192.168.10.1
Assumes the main F/W data (”HE7_V100(NIC_MAIN).bin”) for the for this product is in the current directory D:/
when FTP is executed on the computer.
← Connect to FTP
← Enter the user name
← Move to the firmware directory
← Enter the password (Default: public)
← Current directory position display
← Specify binary transfer mode
← Write the firmware file
← Wait here for the printer to restart
← Quit FTP