U
Overpay Timeout
(The Factory Default Setting for Overpay Timer is “NO”).
To make a change to the Overpay Timeout feature, follow the step by step procedure outlined below.
This setting only needs to be made in the primary dispenser or the EF+ if you have one.
.
Note: The five-position switch and red selection button are located on the dispenser control board.
IMPORTANT: Please note the original switch settings before starting this procedure. You will need to
return the switches to this original setting to assure proper operation after making any changes. As a
convenience, you can enter these original settings in the diagram to the right by simply
marking an “X” for UP or DOWN on each switch.
1.
Activate the Overpay Timer programming mode by setting: Switch 1–ON;
Switch 2-OFF; Switch 3-OFF; Switch 4-ON; Switch 5-ON
2.
Press the red selection button one time.
3.
Advance to the Overpay Timer selection step by setting; Switch 1-ON; Switch 2-OFF; Switch
3-OFF; Switch 4 –OFF; Switch 5-OFF
4.
Press the red selection button Twenty-six times.
5.
Now set switches to desired setting Choice numbers 1 or 2 from the table below. Example: Set
switches to match Choice 2 if you want the Overpay Timer set to yes. Once you’ve made your
selection, press the red selection button one time.
6.
End the programming sequence by resetting the switch to their original settings, and then press
the red selection button one time to put the machine back into service.
Example: When set to YES the machine will use the ERROR TIMEOUT to clear an overpay error. Be
careful in that this can hide real overpay errors.
OVERPAY TIMER CHOICES
CHOICE
SETTING
SWITCH POSITIONS
SW2
SW3
SW4
SW5
1
NO
UP
UP
UP
UP
2
YES
DOWN
DOWN
DOWN
UP
12 345