Stringing Detection Level
(The Factory Default Setting for Stringing Detection Level is “MEDIUM”).
To make a change to the Stringing Detection Level feature, follow the step by step procedure outlined
below.
Note: The five-position switch and red selection button are located on the dispenser control board. For
machines with multiple bill acceptors, these settings must be set on the dispenser control board that
each bill acceptor is plugged into.
IMPORTANT: Please note the original switch settings before starting this procedure. You will need to
return the switches to this original setting to assure proper operation after making any changes. As a
convenience, you can enter these original settings in the diagram to the right by simply marking an “X”
for UP (ON) or DOWN (OFF) on each switch.
1.
Activate the Stringing Detection Level Feature programming mode by
setting: Switch 1–ON; Switch 2-OFF; Switch 3-OFF; Switch 4-ON; Switch 5-ON
2.
Press the red selection button one time.
3.
Advance to the Stringing Detection Level setting step by setting; Switch 1-ON; Switch 2-OFF;
Switch 3-OFF; Switch 4 –OFF; Switch 5-OFF
4.
Press the red selection button thirteen times.
5.
Now set switches to desired setting Choice numbers 1 through 3 as per the cart below. Once
you’ve made your selection, press the red selection button one time. Example: Set switches to
match Choice 3 if you want the Stringing Detection Level set to HIGH (Switch 1-ON; Switch
2-OFF; Switch 3-OFF; Switch 4 –ON; Switch 5-ON)
6.
End the programming sequence by resetting the switch to their original settings, and then press
the red selection button one time to put the machine back into service.
STRINGING DETECTION LEVEL CHOICES
CHOICE
SETTING
(level)
SWITCH POSITIONS
SW2
SW3
SW4
SW5
1
LOW
DOWN
DOWN
DOWN
UP
2
MEDIUM
DOWN
DOWN
UP
DOWN
3
HIGH
DOWN
DOWN
UP
UP
12 345