I
Dispenser Transfer
(
The Factory Default Setting for Dispenser Transfer is “TRANSFER LESS”
).
To make a change to the Dispenser Transfer feature, follow the step by step procedure outlined below.
Note: The five-position switch and red selection button are located on the dispenser control board of
the device marked “Primary”. For machines with multiple bill acceptors, these settings must be set on
the dispenser control board that each bill acceptor is plugged in to.
IMPORTANT: Please note the original switch settings before starting this procedure. You will need to
return the switches to this original setting to assure proper operation after making any changes. As a
convenience, you can enter these original settings in the diagram to the right by simply
marking an “X” for UP or DOWN on each switch.
1.
Activate the Dispenser Transfer programming mode by setting:
Switch 1–ON; Switch 2-OFF; Switch 3-OFF; Switch 4-ON; Switch 5-ON
2.
Press the red selection button one time.
3.
Advance to the Dispenser Transfer selection step by setting;
Switch 1-ON; Switch 2-OFF; Switch 3-OFF; Switch 4 –OFF; Switch 5-OFF
4.
Press the red selection button five times.
5.
Now set switches to desired setting Choice numbers 1 through 3 from the table below.
Example: Set switches to match Choice 2 if you want the Transfer setting set to “Transfer Equal”
Once you’ve made your selection, press the red selection button one time.
6.
End the programming sequence by resetting the switch to their original settings, and then press
the red selection button one time to put the machine back into service.
DISPENSER TRANSFER CHOICES
CHOICE
SETTING
SWITCH POSITIONS
SW2
SW3
SW4
SW5
1
Transfer None
DOWN
DOWN
DOWN
UP
2
Transfer Equal
DOWN
DOWN
UP
DOWN
3
Transfer Less
DOWN
DOWN
UP
UP
12 345