TO MINIMIZE THE RISK OF INJURY DUE TO SUCTION ENTRAPMENT HAZARD:

Pools and spas should utilize a minimum of two drains per pump.

A properly installed and secured ANSI/ASME A112.19.8 approved anti-entrapment suction

cover must be used for each drain.

Each suction cover must be installed at least three (3') feet apart, as measured from the

nearest point to nearest point.

Regularly inspect all covers for cracks, damage and advanced weathering.

If a cover becomes loose, cracked, damaged, broken or is missing, close the pool or spa

immediately, shut off the pump, post a  notice and keep the pool or spa closed until an
appropriate certified cover is properly installed.

Replace drain covers as necessary. Drain covers deteriorate over time due to exposure to

sunlight, pool chemicals and weather.

Avoid getting hair, limbs or body in close proximity to any suction cover, pool drain or outlet.

Use a safety vacuum release system ("SVRS"), suction limiting system or automatic pump

shut-off system.

Disable suction outlets or reconfigure into return inlets.

A clearly labeled emergency shut-off switch for the pool pump and spa jet pump must be in an easily
accessible, obvious place near the pool or spa.  Make sure bathers know where it is and how to use it in case
of emergency.

The Virginia Graeme Baker (VGB) Pool and Spa Safety Act

 creates new requirements for owners and operators of commercial swimming

pools and spas.

Commercial pools or spas constructed on or after December 19, 2008, shall utilize:

(A)  A multiple main drain system without isolation capability with suction outlet covers that meet ASME/ANSI A112.19.8a Suction Fittings

for Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs and either:

(i)   A safety vacuum release system (SVRS) meeting ASME/ANSI A112.19.17 Manufactured Safety Vacuum Release systems (SVRS)

for Residential and Commercial Swimming Pool, Spa, Hot Tub, and Wading Pool Suction Systems and/or ASTM F2387 Standard
Specification for Manufactured Safety Vacuum Release Systems (SVRS) for Swimming pools, Spas and Hot Tubs or

(ii)  A properly designed and tested suction-limiting vent system or
(iii) An automatic pump shut-off system.

Commercial pools and spas constructed prior to December 19, 2008, with a single submerged suction outlet shall use a suction outlet cover that
meets ASME/ANSI A112.19.8a and either:

(A) A SVRS meeting ASME/ANSI A112.19.17 and/or ASTM F2387, or
(B) A properly designed and tested suction-limiting vent system, or
(C) An automatic pump shut-off system, or
(D) Disabled submerged outlets, or
(E) Suction outlets shall be reconfigured into return inlets.

HAZARDOUS PRESSURE:  STAND CLEAR OF PUMP AND FILTER DURING START-UP
Pool and spa circulation systems operate under high pressure.  When any part of the circulating system (i.e.
lock ring, pump, filter, valves, etc.) is serviced, air can enter the system and become pressurized.
Pressurized air can cause the pump housing cover filter lid and valves to violently separate which can result in
severe personal injury or death.  Filter tank lid and strainer cover must be properly secured to prevent violent
separation.  Stand clear of all circulation system equipment when turning on or starting up pump.

CAUTION!:  Electrical controls such as on/off switches, timers, and control systems, etc. should be properly
installed to allow the operation (start-up, shut-down, or servicing) of any pump or filter without requiring the user
to place any portion of his/her body over or near the pump strainer lid or filter lid.  Such installation should allow
the user to stand clear of the filter and pump during system start-up, shut down or servicing of the system.

Before servicing pool and spa equipment, make note of the filter pressure.  Be sure that all controls are set to
ensure the system cannot inadvertently start during service.  Turn off all power to the pump.  

IMPORTANT:

Place filter manual air relief valve in the open position and wait for all pressure in the system to be
relieved.

Before starting the system, fully open the manual air relief valve and place all system valves in the "open"
position to allow water to flow freely from the pool and spa back to the pool or spa.  Stand clear of all pool and
spa equipment and start the pump.  

IMPORTANT:  Do not close filter manual air relief valve until all

pressure has been discharged from the valve and a steady stream of water appears. 

 Observe filter

pressure gauge and be sure it is not higher than the pre-service condition.

ii

Summary of Contents for DYNA-WAVE MPRA Series

Page 1: ...stems and or its affiliated companies in the United States and or other countries Unless noted names and brands of others that may be used in this document are not used to indicate an affiliation or e...

Page 2: ...ION AND OR DEATH The suction at a pool or spa drain or outlet can cause Limb Entrapment When a limb is sucked or inserted into an opening resulting in a mechanical bind or swelling This hazard is pres...

Page 3: ...stem or iii An automatic pump shut off system Commercial pools and spas constructed prior to December 19 2008 with a single submerged suction outlet shall use a suction outlet cover that meets ASME AN...

Page 4: ...ment Have a trained pool professional perform all pressure tests 1 Do not connect system to a high pressure or city water system 2 Use equipment only in a pool or water feature installation 3 Trapped...

Page 5: ...rectly to pump use thread seal to seal connections Do not use pipe dope pipe dope causes cracking in some plastics and may damage components in piping system When connecting pipe to pump with union ha...

Page 6: ...that is there must be at least two main drains connected to the pump whenever it is running see Figure 3 However if two main drains run into a single suction line the single suction line may be equip...

Page 7: ...voltage is less than 90 or more than 110 of rated voltage when motor is running at full load consult power company Grounding Bonding Install ground bond and wire motor according to all current local o...

Page 8: ...terminals labeled L1 and L2 Attach the power leads to these terminals Either wire may attach to either terminal To Wire a Dual Voltage Motor Dual voltage motors have a plug to change from 230 volts fa...

Page 9: ...groove Do not lubricate the trap cover O Ring The original equipment O Ring contains a permanent internal lubricant NOTICE If you replace the O Ring with a non internally lubricated O Ring you may ne...

Page 10: ...instructions for reactivation of the filter 3 Inspect all electrical wiring for damage or deterioration over the shutdown period Have a qualified serviceman repair wiring as needed 4 Inspect and tight...

Page 11: ...etc Wet outer edge with small amount of liquid detergent press ceramic seat into seal plate cavity firmly and squarely with finger pressure see Figure 7 2 If ceramic seat will not locate properly remo...

Page 12: ...35505 1440 14 Trap Basket 1 C8 58P 15A Drain Plug 2 U178 920P 15B Mounting Screw 5 16 14x5 8 2 U30 919SS 16 Base 1 C4 77P 17 Motor Pad 1 C35 45 18 Screw 8 32x7 8 Rd Hd 7 U30 542SS 19 Lock Washer 8 Ext...

Page 13: ...ler is not clogged follow steps 1 through 7 under Removing Old Seal Page 9 check impeller for clogging follow steps 7 through 11under Installing New Seal Page 9 for reassembly 9 Impeller and diffuser...

Page 14: ...For customer support or technical information about this product contact the installer or call Phone 800 831 7133 Fax 800 284 4151 Visit www pentairpool com and staritepool com S752 Rev C 5 15 14...

Page 15: ...o de sus compa as afiliadas en Los Estados Unidos y o en otros pa ses A menos que sea indicado los nombres y marcas de otras compa ias pueden ser utilizados en este documento pero no son utilizados pa...

Page 16: ...iga las instrucciones del manual del propietario Haga que un profesional capacitado en instalaciones en albercas realice todas las pruebas de presi n 1 No conecte el sistema a un sistema de alta presi...

Page 17: ...iones Estar protegida contra una humedad excesiva Permitir el acceso adecuado para los trabajos de servicio de la bomba y de las tuber as Peligro de incendio y de quemaduras Los motores modernos funci...

Page 18: ...tas o flojas Siga los lineamientos que aparecen a continuaci n para la instalaci n de una bomba para reducir los peligros a los usuarios de albercas jacuzzis ba os termales y otros sistemas acu ticos...

Page 19: ...ante s deber cumplir con la versi n m s reciente de la Especificaci n de ASME ANSI para Accesorios de Aspiraci n que se usen en Albercas Jacuzzis Ba os termales y Piscinas de Hidromasaje Pruebas y cer...

Page 20: ...ma o y del tipo requeridos por el c digo Conecte el borne de conexi n a tierra del motor a la tierra del servicio el ctrico La metalizaci n el ctrica del motor se debe hacer a la estructura de la albe...

Page 21: ...rcuito del motor est desconectada antes de trabajar con los cables las conexiones de los cables o con el motor Vuelva a colocar la cubierta del motor y las cubiertas de los otros cables antes de activ...

Page 22: ...mpo de cebado depender del largo vertical de la altura de aspiraci n y del largo horizontal de la tuber a de aspiraci n Si la bomba no ceba verifique que todas las v lvulas est n abiertas que el extre...

Page 23: ...re todas las v lvulas de drenaje y reemplace todos los tapones de drenaje en el sistema de tuber as 9 Cebe la bomba seg n las instrucciones que aparecen en la p gina 7 SERVICIO DE LA BOMBA El servicio...

Page 24: ...U178 920P 15B Tornillo de montaje de 5 16 14 x 5 8 2 U30 919SS 16 Base 1 C4 77P 17 Cojinete del motor 1 C35 45 18 Tornillo 8 32 x 7 8 cabeza redonda 7 U30 542SS 19 Arandela de fijaci n 8 diente alarg...

Page 25: ...ho toque la parte posterior del impulsor AVISO Aseg rese de no cortar ni rayar la superficie pulida del sello ya que el sello gotear con una superficie da ada 8 Atornille el impulsor en el eje hacia l...

Page 26: ...NOTA 12...

Page 27: ...13 NOTA...

Page 28: ...00 10951 West Los Angeles Ave Moorpark CA 93021 805 553 5000 Starite Dyna Wave Pentair Aquatic Systems es marca comercial y o marca registrada de Pentair Aquatic Systems y o de sus compa as afiliadas...

Reviews: