PUMP WARNINGS AND SAFETY INSTRUCTIONS

SUCTION ENTRAPMENT HAZARD:  STAY OFF THE MAIN DRAIN AND AWAY FROM ALL SUCTION
OUTLETS!

Warnings and safety instructions for Pentair Aquatic Systems pumps and other related products are available
at: 

http://www.pentairpool.com/pool-owner/safety-warnings/ 

 Call (800) 831-7133 for additional free copies

of these instructions.  Please refer to 

www.pentairpool.com

 for more information related to Pentair Aquatic

Systems pumps.

FAILURE TO FOLLOW ALL INSTRUCTIONS AND WARNINGS CAN RESULT IN SERIOUS BODILY
INJURY OR DEATH. 

THIS PUMP SHOULD BE INSTALLED AND SERVICED ONLY BY A QUALIFIED POOL

SERVICE PROFESSIONAL. INSTALLERS, POOL OPERATORS AND OWNERS MUST READ THESE
WARNINGS AND ALL INSTRUCTIONS IN THE OWNER'S MANUAL BEFORE USING THIS PUMP. THESE
WARNINGS AND THE OWNER'S MANUAL MUST BE LEFT WITH THE POOL OWNER.

F

THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES A STRONG VACUUM AT THE
MAIN DRAIN AT THE BOTTOM OF YOUR POOL AND SPA.  THIS SUCTION IS SO STRONG THAT IT CAN
TRAP ADULTS OR CHILDREN UNDER WATER IF THEY COME IN CLOSE PROXIMITY TO A POOL OR
SPA DRAIN OR A LOOSE OR BROKEN DRAIN COVER OR GRATE.

THE USE OF UNAPPROVED COVERS OR ALLOWING USE OF THE POOL OR SPA WHEN COVERS ARE MISSING,
CRACKED OR BROKEN CAN RESULT IN BODY OR LIMB ENTRAPMENT, HAIR ENTANGLEMENT, BODY ENTRAP-
MENT, EVISCERATION AND/OR DEATH.

The suction at a pool or spa drain or outlet can cause:

Limb Entrapment:

  When a limb is sucked or inserted into an opening resulting in a mechanical bind or swelling.  This

hazard is present when a drain cover is missing, broken, loose, cracked or not properly secured.

Hair Entanglement:

 When the hair tangles or knots in the drain cover, trapping the swimmer underwater.  This hazard is

present when the flow rating of the cover is too small for the pump or pumps.

Body Entrapment:

  When a portion of the body is held against the drain cover trapping the swimmer underwater.  This

hazard is present when the drain cover is missing, broken or the cover flow rating is not high enough for the pump or
pumps.

Evisceration/Disembowelment:

  When a person sits on an open pool (particularly a child wading pool) or spa outlet and

suction is applied directly to the intestines, causing severe intestinal damage.  This hazard is present when the drain cover
is missing, loose, cracked, or not properly secured.

Mechanical Entrapment:

  When jewelry, swimsuit, hair decorations, finger, toe or knuckle is caught in an opening of an

outlet or drain cover.  This hazard is present when the drain cover is missing, broken, loose, cracked, or not properly
secured.

NOTE: 

ALL SUCTION PLUMBING MUST BE INSTALLED IN ACCORDANCE WITH THE LATEST NATIONAL AND LOCAL

CODES FOR SWIMMING POOLS, SPAS AND HOT TUBS, INCLUDING NSPI STANDARDS AND CPSC GUIDELINES.

READ AND KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

For Pool and Spa 

Pumps (Non SVRS Pumps)

i

Summary of Contents for DYNA-WAVE MPRA Series

Page 1: ...stems and or its affiliated companies in the United States and or other countries Unless noted names and brands of others that may be used in this document are not used to indicate an affiliation or e...

Page 2: ...ION AND OR DEATH The suction at a pool or spa drain or outlet can cause Limb Entrapment When a limb is sucked or inserted into an opening resulting in a mechanical bind or swelling This hazard is pres...

Page 3: ...stem or iii An automatic pump shut off system Commercial pools and spas constructed prior to December 19 2008 with a single submerged suction outlet shall use a suction outlet cover that meets ASME AN...

Page 4: ...ment Have a trained pool professional perform all pressure tests 1 Do not connect system to a high pressure or city water system 2 Use equipment only in a pool or water feature installation 3 Trapped...

Page 5: ...rectly to pump use thread seal to seal connections Do not use pipe dope pipe dope causes cracking in some plastics and may damage components in piping system When connecting pipe to pump with union ha...

Page 6: ...that is there must be at least two main drains connected to the pump whenever it is running see Figure 3 However if two main drains run into a single suction line the single suction line may be equip...

Page 7: ...voltage is less than 90 or more than 110 of rated voltage when motor is running at full load consult power company Grounding Bonding Install ground bond and wire motor according to all current local o...

Page 8: ...terminals labeled L1 and L2 Attach the power leads to these terminals Either wire may attach to either terminal To Wire a Dual Voltage Motor Dual voltage motors have a plug to change from 230 volts fa...

Page 9: ...groove Do not lubricate the trap cover O Ring The original equipment O Ring contains a permanent internal lubricant NOTICE If you replace the O Ring with a non internally lubricated O Ring you may ne...

Page 10: ...instructions for reactivation of the filter 3 Inspect all electrical wiring for damage or deterioration over the shutdown period Have a qualified serviceman repair wiring as needed 4 Inspect and tight...

Page 11: ...etc Wet outer edge with small amount of liquid detergent press ceramic seat into seal plate cavity firmly and squarely with finger pressure see Figure 7 2 If ceramic seat will not locate properly remo...

Page 12: ...35505 1440 14 Trap Basket 1 C8 58P 15A Drain Plug 2 U178 920P 15B Mounting Screw 5 16 14x5 8 2 U30 919SS 16 Base 1 C4 77P 17 Motor Pad 1 C35 45 18 Screw 8 32x7 8 Rd Hd 7 U30 542SS 19 Lock Washer 8 Ext...

Page 13: ...ler is not clogged follow steps 1 through 7 under Removing Old Seal Page 9 check impeller for clogging follow steps 7 through 11under Installing New Seal Page 9 for reassembly 9 Impeller and diffuser...

Page 14: ...For customer support or technical information about this product contact the installer or call Phone 800 831 7133 Fax 800 284 4151 Visit www pentairpool com and staritepool com S752 Rev C 5 15 14...

Page 15: ...o de sus compa as afiliadas en Los Estados Unidos y o en otros pa ses A menos que sea indicado los nombres y marcas de otras compa ias pueden ser utilizados en este documento pero no son utilizados pa...

Page 16: ...iga las instrucciones del manual del propietario Haga que un profesional capacitado en instalaciones en albercas realice todas las pruebas de presi n 1 No conecte el sistema a un sistema de alta presi...

Page 17: ...iones Estar protegida contra una humedad excesiva Permitir el acceso adecuado para los trabajos de servicio de la bomba y de las tuber as Peligro de incendio y de quemaduras Los motores modernos funci...

Page 18: ...tas o flojas Siga los lineamientos que aparecen a continuaci n para la instalaci n de una bomba para reducir los peligros a los usuarios de albercas jacuzzis ba os termales y otros sistemas acu ticos...

Page 19: ...ante s deber cumplir con la versi n m s reciente de la Especificaci n de ASME ANSI para Accesorios de Aspiraci n que se usen en Albercas Jacuzzis Ba os termales y Piscinas de Hidromasaje Pruebas y cer...

Page 20: ...ma o y del tipo requeridos por el c digo Conecte el borne de conexi n a tierra del motor a la tierra del servicio el ctrico La metalizaci n el ctrica del motor se debe hacer a la estructura de la albe...

Page 21: ...rcuito del motor est desconectada antes de trabajar con los cables las conexiones de los cables o con el motor Vuelva a colocar la cubierta del motor y las cubiertas de los otros cables antes de activ...

Page 22: ...mpo de cebado depender del largo vertical de la altura de aspiraci n y del largo horizontal de la tuber a de aspiraci n Si la bomba no ceba verifique que todas las v lvulas est n abiertas que el extre...

Page 23: ...re todas las v lvulas de drenaje y reemplace todos los tapones de drenaje en el sistema de tuber as 9 Cebe la bomba seg n las instrucciones que aparecen en la p gina 7 SERVICIO DE LA BOMBA El servicio...

Page 24: ...U178 920P 15B Tornillo de montaje de 5 16 14 x 5 8 2 U30 919SS 16 Base 1 C4 77P 17 Cojinete del motor 1 C35 45 18 Tornillo 8 32 x 7 8 cabeza redonda 7 U30 542SS 19 Arandela de fijaci n 8 diente alarg...

Page 25: ...ho toque la parte posterior del impulsor AVISO Aseg rese de no cortar ni rayar la superficie pulida del sello ya que el sello gotear con una superficie da ada 8 Atornille el impulsor en el eje hacia l...

Page 26: ...NOTA 12...

Page 27: ...13 NOTA...

Page 28: ...00 10951 West Los Angeles Ave Moorpark CA 93021 805 553 5000 Starite Dyna Wave Pentair Aquatic Systems es marca comercial y o marca registrada de Pentair Aquatic Systems y o de sus compa as afiliadas...

Reviews: