48
Feed pump runs constantly,
will not turn off
Manual override switches
in “on” position
Turn off manual switch on
control box
SYMPTOMS
PROBABLE CAUSE
REMEDY
Spectra Watermakers Newport Troubleshooting Procedures
No lights or display, system
does not operate
- Remote display not connected
- No power to control box
- Check display cable connec-
tions at back of display and at
control box
- Check and reset main DC
supply breaker
- Check for voltage (12 or
24vDC) at control box power
input studs
- Try manual bypass switches;
if pumps run, then control or
display is defective
Feed pump runs with loud
noise
- Intake blocked
- Air in system
- Check thru-hull valve
- Check sea strainer for leaks
- Check FWF module for leaks
- Re-prime system (restart)
Pumps run intermittently,
cycling on/off
System operating in flush mode
(DC models)
- System will time out, or
manually stop with the Start/
Stop button
Display activates, but pump
will not run
- loose or broken pump wire
connection
- bad pump relay
- tanks are full
- Check wiring at terminal
block inside MPC
- Test power relay, replace
- Replace fuse (mini automo-
tive type ATM)
- Check tanks– system cannot
be started if tanks are full.
System runs, no product
water delivered to water
tanks, GHP bar graph
shows OK, “Good” LED
activated
- diversion valve inoperative
wiring fault.
- disconnected
or
broken
product tubing
- diversion valve plunger
- Check wiring at diversion
valve and inside control box
- Check product tubing
- Disassemble and clean
diverion valve plunger or re-
place valve (contact factory)
System runs, no product
water delivered to water
tanks, GPH bar graph
shows OK, “reject” LED
activated
- high salinity of product
water, causing system to
reject water
- salinity probe out of cali-
bration or defective, bad
cable
- chlorine damage to mem-
branes
- pressure relief valve open
- Check for low feed pressure,
close pressure relief valve
- Check for leaks at high pres-
sure hoses
- Test product water with hand-
held tester– if over 500ppm
for 1 hour, contact factory
Close Valve
Summary of Contents for Newport 1000
Page 2: ...2...
Page 4: ...4...
Page 6: ...6...
Page 8: ...8...
Page 38: ...38 Push the Auto Flush button press Stop press Auto Flush again...
Page 59: ...59 Z BRANE OPERATION MANUAL...