20
Wiring 110 & 220 Volt AC Versions
AC Systems will Have:
Fresh water flush cable, these wires have no polarity
Two Power inlet harnesses with terminal blocks,
A 75’(26 M) cable with connectors for the MPC-3000 control display,
Clark Pump Module harness consisting of the Rotoflow cable, salinity probe cable, and the
diversion valve (no polarity) cable.
The MPC-3000 Control box houses the
V
ariable
F
requency motor
D
rive and the MPC-3000
control board. The
VFD
serves several functions. First it allows the machine to run with al-
most any AC frequency. Regardless of the input conditions the drive will hold a constant
motor speed. The motor controller output is three phase AC to the motor. The control will
“soft starts” the motor. This allows the watermaker to be run on a very small generator if
desired. The motor control also slows the motor to the flush and service speeds. The VFD
has over-temperature shutdown protection.
Do not install it in hot or poorly ventilated
locations.
Manual Control
Switches
Variable Frequency Drive
(VFD) AC Versions
MPC– 3000 Controller
Feed Pump Power
AC Inlet
(3 wires)
DC inlet
(2 wires)
Clark Pump Harness:
Stroke sensor cable
Salinity probe cable
Diversion valve cable
Flush Valve cable
Display cable