Step 1: Flush the system twice.
Push the “Auto Flush” button
on the MPC-3000 dis-
play, when the first flush has been completed,
press “Stop”
to cancel the 5 day interval
timer, then
press “Auto Flush” again
.
•
Step 2:
Remove the quick disconnect fitting
from the brine discharge outlet of the
Clark pump, and
replace with the quick disconnect hose
from your service kit,
and lead the hose to a 5 gallon bucket.
•
Step 3: Use the manual switches on the feed pump module,
Set to “Run Auto” and
“Flush Manual”
to fill the bucket with 2 gallons of fresh unchlorinated water. When the
bucket has reached the desired level
Set both switches to “Auto”
•
Step 4:
Connect the hose
, using the garden hose barb fitting from your service kit,
to
the service port
of the fresh water flush module. Lead the hose into the bucket.
Turn
the service valve
on the fresh water flush module 180°, so the intake is now coming
from the bucket.
•
Step 5:
Mix the cleaning chemical
compound into the water in the bucket. Heat the
solution to a maximum of 120F (50C) if possible for faster results.
•
Step 6:
Make sure the pressure relief valve on the Clark pump is Open
(unpressurized).
•
Step 7:
Set the switches on the pump module to “Service System” and
“Flush Auto”
to turn on the feed pump. Circulate the chemical in the system for approxi-
mately 25 minutes. Allow to soak for several hours or overnight if the solution is cold.
Run the pump occasionally to agitate the solution.
Set both switches to Auto
when
finished.
•
Step 8:
Turn off the control system (DC) power
to reset the MPC-3000 controls.
Replace the brine overboard hose
.
Remove the Inlet Service hose
and
turn
the Service valve to the Run position
.
•
•
Step 9: To avoid damaging the membranes,
Follow the “New System Startup” In-
structions
to Purge the chemicals out of the System.
Spectra Cleaning Compound (SC-2 or SC-3) must be mixed with fresh water at a ratio of 1 con-
tainer of compound to 3 gallons (12L) of unchlorinated water to have the proper solution. An aver-
age of 4 gallons (16L) is already present inside a system. This water has to be figured into the mix-
ture. You will need to use two cans of cleaner. SC-2 and SC-3 are never mixed together. Do not use
them for storage pickling solution.
Warning! The pressure relief valve on the Clark pump must be open for this procedure
or membrane damage may result. Maximum pressure 50 psi.
Note: Procedures are the same for the SC-2 and SC-3 cleaners
MEMBRANE CLEANING PROCEDURE