RIPPLE PUMPS INSTRUCTIONS MANUAL mod. N. 1 FAR - s/n V-0067 / V-0068 – Machinery
world
C.2009573
C2
The product cannot pass between the two rotors and goes to occupy the
space formed between the rotary lobes and the pump casing, so that it is
directed towards the outlet.
2.3 PROGRAMMED AND UNPROGRAMMED USAGE
WARNING !
This machine was designed to pump highly viscous liquids and/or
containing solid particles in suspension.
It is not to be used to transfer:
. products containing abrasive substances
. noxious toxic chemical products
. alcohol based products
. explosion risk products
2.4 SPECIFICATIONS – FLUIDS AND ELECTRIC ENERGY
SPECIFICATIONS:
Model No. 1 FAR
– Serial number
V-0067 / V-0068
, made up of:
•
AISI 316 stainless steel sanitary shell:
inlet/outlet 1 1/2" PV
•
Gear case in cast iron
•
AISI 316 stainless steel shafts
•
Rotors: AISI 316 hubs, covered in nitrile rubber - P/N A151267 (max
temperature 57°C)
•
Gear motor: BONFIGLIOLI type VF49/F, 0,37 kW
FLUIDS AND ELECTRIC ENERGY:
•
Electric energy: 0,37 kW, 2 poles, 415 V, 50 Hz
Working conditions:
MAXIMUM SERVICE SPEED:
. 600 rpm (mod. N. 0; N. 0.5, N. 1; N.2)
. 400 rpm (mod. N. 2,5; N. 3; N. 4; N. 6)
MAXIMUM SERVICE PRESSURE: 7 bar
MAXIMUM SERVICE TEMPERATURE:
57°C (standard rotors)
82°C – 104°C – over 104°C (undersized rotors)
See annex 1 page. 1 pos. 10, for choosing rotors according to service
temperature.
2.5 MACHINE NOISE EMISSION