7.
Remove the front panel assembly. (Refer to
8.
Remove the rear panel assembly. (Refer to
.)
9.
Remove the IO-255 assembly. (Refer to
10. Remove the DCP-61 board. (Refer to
11. Remove the handle assembly. (Refer to
12. Remove the front lens assembly. (Refer to
.)
Procedure
1.
Remove the tape.
2.
Remove the two precision screws (M2 x 4) to detach the SE-1110 board.
3.
Remove the two screws (TP2 x 5) to detach the GY bracket S.
GY Bracket S
SE-1110 board
Tape
Precision screws
(M2 x 4)
TP2 x 5
4.
Remove the main gasket C.
5.
Remove the precision screw (M2 x 4) to detach the ground plate (A).
6.
Remove the precision screw (M2 x 4) to detach the heat sink (A).
7.
Remove the precision screw (M2 x 4) to detach the ground plate (B).
8.
Remove the screw (P2.6 x 5) to detach the outside bottom bracket.
PMW-160/PMW-150/PMW-EX260
2-39