2-25
UWP Series
Procedure
1.
Set the spectrum analyzer as below:
CENTER FREQUENCY :
U30 model
; 578.125 MHz
±
1 kHz
U42 model
; 650.125 MHz
±
1 kHz
CE62 model ; 810.000 MHz
±
1 kHz
CE67 model ; 850.000 MHz
±
1 kHz
KR model
; 746.125 MHz
±
1 kHz
REFERENCE LEVEL
: 20 dBm (10 dBm ;
KR model only)
FREQUENCY SPAN
: 500kHz (50 kHz/DIV)
RBW (resolution band width) : 1 kHz
VBW (video band width)
: 1 kHz
ATT
: 20 dB
2.
Set the carrier frequency level (the center frequency
level of the spectrum analyzer) to the REFERENCE
LEVEL when no signals are input.
3.
Input 1 kHz,
_
30 dBV (
_
27.8 dBm) signal to the MIC
INPUT connector (with Mic input cable) from the audio
analyzer (oscillator).
4.
At this time, confirm that the bandwidth at the level
_
23 dB lower than REFERENCE LEVEL is in
specification.
Specification :
bandwidth = 100 kHz or less
v:10 dB/div
H:50 kHz/div
_
23 dB
fc
REFERENCE LEVEL
band width
100 kHz or less