2-28
UWP Series
1. Current Consumption Check
Equipment and Tools
.
DC power supply
DC output voltage :
+
9.0Vdc
±
0.1 V
.
DC ammeter
.
Digital volt meter (or Digital multimeter)
Switch and Control Setting
URX-M2 Front panel
Channel setting :
U30 model
; Group 03, 32-01 channel (578.125 MHz)
U42 model
; Group 03, 44-01 channel (650.125 MHz)
CE62 model ; Group 04, 63-32 channel (810.000 MHz)
CE67 model ; Group 04, 68-32 channel (850.000 MHz)
KR model
; Group 12, 60-01 channel (746.125 MHz)
RF Squelch :
OFF (For setting, refer to “Setting the
Squelch OFF mode” on page 2-29)
Procedure
1.
Remove the case (upper and lower) of the URX-M2
from the UWP unit.
2.
Connect a DC power supply (
+
9.0Vdc
±
0.1 V) as
shown in the figure below.
DC ammeter indication level
(under no-RF signal input and SQUELCH OFF mode)
: 190 mA or less
DC ammeter
MB-1129 board (B side)
DC power supply
(DC output voltage :
+
9.0
±
0.1 V)
Solder
Solder
CN301
Pin No.6
Pin No.7
2. Reference Frequency (4 MHz oscillation
frequency) Adjustment
Equipment and Tools
.
DC power supply
DC output voltage :
+
9.0Vdc
±
0.1 V
.
Frequency counter
Switch and Control Setting
URX-M2 Front panel
Channel setting :
U30 model
; Group 03, 32-01 channel (578.125 MHz)
U42 model
; Group 03, 44-01 channel (650.125 MHz)
CE62 model ; Group 04, 63-32 channel (810.000 MHz)
CE67 model ; Group 04, 68-32 channel (850.000 MHz)
KR model
; Group 12, 60-01 channel (746.125 MHz)
RF Squelch : OFF (For setting, refer to “Setting the
Squelch OFF mode” on page 2-29)
IC504 CT501
Frequency counter
MB-1129 board (A side)
Pin No.4
Summary of Contents for UWP-V1
Page 4: ......
Page 20: ......
Page 94: ...3 6 UWP Series URX M2 3 2 3 URX M2 4 9 11 6 10 10 2 3 1 8 8 9 5 7 ...
Page 130: ......
Page 131: ...4 1 UWP Series 4 1 Section 4 Block Diagrams and Circuit Descriptions ...
Page 142: ......
Page 148: ......
Page 163: ......
Page 164: ...Printed in Japan Sony Corporation 2008 6 16 2008 UWP V1 V2 V6 X7 X8 U CE KR E 9 976 937 01 ...