1-6
UWP Series
1-2-2. Precaution When Replacing EEPROM (IC401)
When the EEPROM (IC401) is replaced with the new EEPROM, the same data that have been stored in
the removed EEPROM must be written into the newly mounted EEPROM.
1-2-3. Error Messages
When an error occurs, any of the following error messages can be generated by the self-diagnostics
function that is built-in the UTX-H2 and can appear on the display section.
Message
Error contents
Remedial measure
Err01
An error occurs in the backup
Check the EEPROM (IC401) and its peripheral
memory data.
circuits.
Err02
An error occurs in the PLL
Check the PLL synthesizer circuit (IC102, CP101 on
synthesizer circuit.
the MB-5 board and its peripheral circuits).
Err03
Power supply voltage has exceeded
Use the equipment with the power supply of the
the range of allowable limits.
specified voltage range.