2-4
UWP Series
MM-SMA conversion connector
SMA-BNC conversion connector
Frequency counter
RF-131 board
(A side)
CN301
2. Carrier Frequency Adjustment
Equipment and Tools
.
DC power supply
DC output voltage :
+
3.0
±
0.1 Vdc
.
DC ammeter
.
Frequency counter
.
Adjustor (SONY Part No. 7-721-052-81)
.
MM-SMA conversion connector
(SONY Part No. J-6402-490-A)
.
SMA-BNC conversion connector
(SONY Part No. J-6402-480-A)
Switch and Control Setting
Transmission channel
U30 model
; 32-01 channel (578.125 MHz)
U42 model
; 42-01 channel (650.125 MHz)
CE62 model ; Group 00, 63-32 channel (810.000 MHz)
CE67 model ; Group 00, 68-32 channel (850.000 MHz)
KR model
; 60-01 channel (746.125 MHz)
Attenuation setting :
0 dB
Accumulated time setting :“00 : 00”
n
Note down the setting position before the adjustment.
After the Adjustment complete, set the original position.
Connections
(For connecting the DC power supply, refer to step
“3. Connecting the DC power supply” in Section 2-1-2.)
Procedure
1.
Connect a frequency counter to the antenna terminal
(CN301/RF-131 board) via the MM-SMA conversion
connector and the SMA-BNC conversion connector.
2.
Adjust
1
CT621 so that the frequency counter reading
meets the following specification.
Specification :
Carrier frequency mentioned below.
U30 model
; 578.125 MHz
±
1 kHz
U42 model
; 650.125 MHz
±
1 kHz
CE62 model ; 810.000 MHz
±
1 kHz
CE67 model ; 850.000 MHz
±
1 kHz
KR model
; 746.125 MHz
±
1 kHz
Adjustment :
1
CT621/CPU-422 board (B side)
(Refer to page 2-3 for the adjustment location.)
Summary of Contents for UWP-V1
Page 4: ......
Page 20: ......
Page 94: ...3 6 UWP Series URX M2 3 2 3 URX M2 4 9 11 6 10 10 2 3 1 8 8 9 5 7 ...
Page 130: ......
Page 131: ...4 1 UWP Series 4 1 Section 4 Block Diagrams and Circuit Descriptions ...
Page 142: ......
Page 148: ......
Page 163: ......
Page 164: ...Printed in Japan Sony Corporation 2008 6 16 2008 UWP V1 V2 V6 X7 X8 U CE KR E 9 976 937 01 ...