65
Chapter 5 Operating the AIT Drive
10
When the initialization ends, press the [CANCEL] button twice to return to
the menu, select “7.Move Tape”, then press the [ENTER] button.
11
Use the
V
and
v
buttons to set the
element address of the slot where
the cleaning cartridge is set, then
press the [ENTER] button.
12
Make sure that “DR” is selected, then press the [ENTER] button.
13
When “[ENTER] to activate”
appears, press the [ENTER] button.
The cleaning cartridge moves to the AIT drive, and cleaning begins.
Cleaning takes about 30 seconds. (No message is displayed to indicate that
cleaning is completed. Please wait for about 30 seconds.)
14
When cleaning is finished, use the Move Tape Menu to move the cleaning
cartridge form the AIT drive to the AIT library.
15
Use the “Eject From Library” of the Eject/Insert Menu to take out the
cleaning cartridge.
16
Press the [CANCEL] button three times to return to the status display.
Note
If an error message appears, perform one of the following.
• When “Cleaning Tape at EOM” is displayed, a spent cleaning cartridge is set
in the AIT drive. Replace the spent cleaning cartridge with a new one.
• When “Clean failure” is displayed, cleaning failed. Repeat the cleaning
procedure.
Source 01
Destination DR
Source 01
Destination DR
[ENTER] to activate