Ref No. (Address)
Color
Name
Function
D4405 (G-2)
Green
SSP-27B POWER indicator
This indicator is lit when the DC-DC converter is in the normal state.
D501 (C-1)
Green
DEC-177 status
Factory use only
D521 (C-1)
Green
DEC-177 KEYCHECK status
Factory use only
D522 (C-1)
Red
DEC-177 CRC status
Factory use only
D520 (C-1)
Green
DEC-177 C3 startup status
Factory use only
(This indicator blinks when IC1101 on the DEC-177 board is
activated.)
D500 (C-1)
Green
DEC-177 V6 startup status
Factory use only
(This indicator blinks when IC400 on the DEC-177 board is
activated.)
D1801 (H-3)
Green
SSP-27B IC1801 startup status Factory use only (This indicator is lit when IC1801 is activated.)
D4101 (B-6)
Green
SSP-27B IC4001 startup status This indicator is blinks when IC4001 is activated.
D4005 (B-6)
Green
SSP-27B FPGA startup status This indicator is lit when FPGA on the SSP-27B board is activated.
D2625 (D-7) to D2628 (D-7) Green
SSP-27B IC2401 startup status Factory use only (This indicator blinks when IC2401 is activated.)
D101 (D-7) to D104 (D-7)
Green
SSP-27A status
Factory use only
D3301 (H-4) to D3304 (H-4) Green
SSP-27B IC3201 startup status Factory use only (This indicator blinks when IC3201 is activated.)
D405 (C-1) to D408 (C-1)
Green
DEC-177 status
Factory use only
4. DP-455
board
n
The parts location on the board is shown in parentheses.
Ref No. (Address)
Color
Name
Function
D113 (B-1)
Red
DP-455 POWER indicator This indicator is lit when the DC-DC converter is in the normal state.
D114 (A-1)
Red
DP-455 POWER indicator This indicator is lit when the DC-DC converter is in the normal state.
D110 (A-3)
Green
READY indicator
This indicator blinks during the startup and it is lit in the standby state.
D109 (A-3)
Green/Red LAN indicator
Factory use only (This indicator blinks during the network communication.)
D108 (B-3)
Green
PLAY indicator
This indicator is lit during the reproduction and it turns off when the
reproduction is stopped.
D111(B-3)
Green
HDD access indicator
Factory use only (This indicator is lit during the access to HDD.)
D112 (B-3)
Amber/
Red
ALARM indicator
Amber: This indicator blinks when there is any abnormal state that
may cause operational problem.
Red:
This indicator is lit when there is abnormal state that pre-
vents the reproduction.
D104 (C-2) to D105 (C-2) Green
Factory use only
D106 (C-2) to D107 (C-2) Green
Factory use only
D201 (C-2) to D202 (C-2) Green
Factory use only
D203 (C-2) to D204 (C-2) Green
Factory use only
D205 (C-2) to D206 (C-2) Green
Factory use only
D110
D108
D109
D111
D112
D113
D114
D104
D106
D201
D203
D205
D105
D107
D202
D204
D206
A
1
2
3
B
C
D
Summary of Contents for LMT-300
Page 1: ...MEDIA BLOCK LMT 300 SERVICE MANUAL 1st Edition Revised 4 ...
Page 4: ......
Page 8: ......
Page 28: ......
Page 46: ......
Page 78: ......
Page 92: ...Sony Corporation LMT 300 SY J E 9 968 672 05 Printed in Japan 2012 7 32 2009 ...