2-4 (E)
LMT-300
Event
classi
fi
cation
Event display
Description
Remedy
0000
INFORMATION
SHOW START
FAILED
VERIFY:<Verify
Status> <cplid>
The CPL veri
fi
cation status of <cplid> failed in
the start of projection because it is <Verify
Status>.
Operation state information
SHOW START
FAILED
VALIDATE:<Validate
Status> <cplid>
The CPL validity veri
fi
cation status failed in the
start of projection because it is <Validate
Status>.
KDM KEY TYPE
MISSING:<kdmid>
KeyType in KDM of <kdmid> did not exist.
SHOW START
FAILED MISMATCH
CONTENT AUTH
<cplid>
The start of projection failed because CPL
ContentAuthenticator of <cplid> does not
coincide.
SHOW START
FAILED MISMATCH
KEY TYPE <cplid>
The start of projection failed because CPL Key-
Type of <cplid> does not coincide with Key-
Type speci
fi
ed by KDM.
SHOW START
FAILED.
TDL ERROR MB
<cplid>
The start of projection failed because the
certi
fi
cate information of MediaBlock is not
described in TDL of KDM for CPL of <cplid>.
SHOW START
FAILED.
TDL ERROR PRJ
<cplid>
The start of projection failed because the
certi
fi
cate information of projector is not
described in TDL of KDM for CPL of <cplid>.
KDM ALL DELETED
All KDMs are deleted.
SHOW START
FAILED.
SUBTITLE UNWRAP
FAILURE. <cplid>
The start of projection failed because the
unwrapping of CPL caption
fi
le of <cplid> has
failed.
CC UNWRAP
FAILURE. <cplid>
The unwrapping of closed caption
fi
le failed.
Mismatch HI/VI
channel label
HI/VI channel con
fi
guration labels are different
in reels
S2S CLIENT
TRANSFER START
Transfer of S2S client was started.
S2S CLIENT
TRANSFER END
Transfer of S2S client was ended.
DCP TRANSFER
START
Transfer of S2S server was started.
DCP TRANSFER
END
Transfer of S2S server was ended.
DCBLOCK Version
mismatch
DCBLOCK version mismatch
0004
ERROR
MPU BOOT ERR
An error occurs during MPU start.
Replace the PU-131 board.
0006
ERROR
MPU DDR ERR
An error occurs in the memory of MPU.
Replace the DDR SDRAM
DIMM module of a PU-131
board assembly.
0007
ERROR
PU LOW VLT
The decrease in the supply voltage of the
PU-131 board is detected.
Check that a detection
switching regulator is not
defective.
0008
WARNING
BTRRY DFCT
The voltage decrease in a spare battery for
commercial AC power stop is detected.
Replace the four backup
batteries of two fan units.
0011
ERROR
PU SRAM ERR
An error occurs in SRAM on the PU-131 board.
Replace the PU-131 board.
0028
WARNING
THERMO ERR
An error occurs in the temperature sensor on
the PU-131 board.
Replace the PU-131 board.
Summary of Contents for LMT-300
Page 1: ...MEDIA BLOCK LMT 300 SERVICE MANUAL 1st Edition Revised 4 ...
Page 4: ......
Page 8: ......
Page 28: ......
Page 46: ......
Page 78: ......
Page 92: ...Sony Corporation LMT 300 SY J E 9 968 672 05 Printed in Japan 2012 7 32 2009 ...