1-10 (E)
LMT-300
5. CP-406
board
n
The address on the board is indicated in parenthesis.
Ref No. (Address) Name
Function
Remarks
S101 (C-2)
CP-406 board reset
switch
The CP-406 board is reset by pressing this switch.
n
This switch is factory use only. Do not press it in the normal operation.
S102 (C-2)
CP-406 board
adjustment switch
Factory setting: OFF
S102-1: SMS
stop
switch
Set this switch before installation.
ON:
SMS
stop
OFF:
Normal
operation
S102-2 to 8:
Factory use only (always OFF in the normal operation)
6. IO-243
board
n
The address on the board is indicated in parenthesis.
Ref No. (Address) Name
Function
Remarks
S101 (C-2)
IO-243 board reset
switch
The IO-243 board is reset by pressing this switch.
n
This switch is factory use only. Do not press it in the normal operation.
S102 (C-2)
IO-243 board
adjustment switch
Factory setting: OFF
S102-1 to 8:
Factory use only (always OFF in the normal operation)
A
1
2
3
B
C
D
E
S102
S101
ON
OFF 1 2 3 4 5 6 7 8
A
1
2
3
B
C
D
E
S102
S101
ON
OFF 1 2 3 4 5 6 7 8