4-20
CCU-TX7 (E)/V1
4-4-4. B-Y Crosstalk Adjustment
Note :
Make sure that 45 MHz frequency on the YM-15
board (CA-TX7/TX7P) is correct.
Equipment
:
Oscilloscope
To be extended :
YD-26 board
Test point
:
TP17 (GND: E8)/YD-26 board
Adjusting point :
1
RV13 (OFFSET ADJ)/YD-26 board
Specification
:
A = 0
±
3 mV
4-4-5. C 1st AGC Adjustment
Equipment
:
Oscilloscope
To be extended :
YD-26 board
Preparation :
.
S1 (AUTO/MANU)/YD-26 board
→
"AUTO"
.
S4 (C 2nd AGC)/YD-26 board
→
"OFF"
Test point
:
TP17 (GND: E8)/YD-26 board
Adjusting point :
1
RV10 (C AGC CONT)/YD-26 board
Specification
:
A = 350
±
20 mV
SYNC
A
BLKG
A