4-18
CCU-TX7 (E)/V1
4-3-12. Y Output Level Adjustment
Equipment
:
Oscilloscope
To be extended :
YD-26 board
Preparation
:
.
S3 (Y 2nd AGC)/YD-26 board
→
→
→
→
→
"ON"
Test point
:
TP11 (GND: E6)/YD-26 board
Adjusting point :
1
RV9 (Y LEVEL)/YD-26 board
Specification
:
A = 700
±
7 mV p-p
4-4. CHROMA Cable Compensation
System Adjustment
4-4-1. 45 MHz Carrier Level Adjustment
Equipment
:
Oscilloscope
To be extended :
YD-26 board
Test point
:
TP16 (GND: E8)/YD-26 board
Adjusting point :
1
RV15 (C CARR LEVEL)/
YD-26 board
Specification
:
A = 400
±
20 mV p-p
(BW LIMIT/Oscilloscope
→
"OFF" )
A
A
YD-26
YD-26 Board
(A SIDE)
RV1
Y AGC CONT
RV10
C AGC CONT
S2
CABLE LENGTH
S1
RV2
BLACK S/H
RV5
SYNC S/H
RV6
VCO DC SET
RV12
B-Y LEVEL
RV13
OFFSET ADJ
RV14
PLL SET
RV15
C CAR LEV
RV8
FL3
SAMPL S/H
RV4
SAMPL GATE
RV3
B-Y CARR BAL
RV11
TP9
TP16
R-Y CARR BAL
RV16
Y LEVEL
RV9
RV17
R-Y LEVEL
RV18
90
°
SET
S3
Y 2'nd AGC
S4
C 2'nd AGC
LV1
OFF
ON
OFF
ON
MODE
AUTO
MAN
RV24
RV7
Y CAR LEVEL
Y CARR BAL
Y OFFSET ADJ
Y RF TUNE
TP2
E1
E7
E4
TP15
E3
E2
E8
E5
E6
E9
E16
TP3
TP4 TP7
TP6
TP5
TP13
TP1
TP14
TP26
TP10
TP20
TP21
TP12
TP19
TP11
TP18
TP8