1-11
CCU-TX7 (E)/V1
21
Specifications
General
Power requirements
CCU-TX7: 120 VAC, 50/60 Hz
CCU-TX7P: 220 to 240 VAC, 50/
60 Hz, 0.45 A
10.5 to 17.0 VDC
Power consumption
95 W
Cable length
1500 m max. (diameter: 14.5 mm )
Operating temperature
5
°
C to 40
°
C (41
°
F to 104
°
F)
Mass
About 8.45 kg (18 lb 10 oz)
Dimensions (w/h/d, excluding protruding parts)
200
×
164
×
370 mm (7
7
/
8
×
6
1
/
2
×
14
5
/
8
inches)
Input connectors
GENLOCK
BNC type (2, loop-through)
VBS/BS, 1.0Vp-p, 75
Ω
RETURN VIDEO 1, 2
BNC type (2 each, loop-through)
VBS, 1.0 Vp-p, 75
Ω
PROMPT VIDEO BNC type (2, loop-through)
VBS, 1.0 Vp-p, 75
Ω
PGM IN
XLR 3-pin (1)
Output connectors
VBS1, VBS2
BNC type (1 each)
VBS, 1.0 Vp-p, 75
Ω
Y/R–Y/B–Y
1)
BNC type (2 each)
Y: 1.0 Vp-p, 75
Ω
R–Y/B–Y: 700 mVp-p (CCU-
TX7)/525 mVp-p (CCU-TX7P),
75
Ω
R/G/B
1)
BNC type (2 each)
700 mVp-p, 75
Ω
PIX
BNC type (1), 1.0 Vp-p, 75
Ω
WF
BNC type (1)
700 mVp-p, 75
Ω
Encoded output: 1.0 Vp-p, 75
Ω
WF MODE
4-pin (1)
MIC OUT
XLR 3-pin (2)
0 dBu/–20 dBu balanced,
2 channels
Y/C
1)
BNC type (2 each)
Y: 1.0 Vp-p, 75
Ω
C: 286 mV (CCU-TX7)/300 mV
(CCU-TX7P) (burst), 75
Ω
SDI
2)
BNC type (2)
SDI format, 270 Mbps, SMPTE
259M (CCU-TX7)/CCIR656-III
(CCU-TX7P)
SYNC
BNC type (1)
0.3 Vp-p, 75
Ω
, negative polarity
Camera control input/output connectors
CAMERA
Triaxial (1)
COAX
BNC type (1)
REMOTE
10-pin (1)
INTERCOM/TALLY
D-sub 25-pin (1)
4W/2W
TALLY: 24 VDC, TTL level or
contact signals switchable
RTS
XLR 3-pin (2)
RS232C
D-sub 25-pin (2)
INTERCOM(on the front panel)
XLR 5-pin (1)
Accessories supplied
AC power cord (1)
Power cord plug retainer (1)
Number plates (1 set)
Operation Manual (1)
Optional accessories
COU-TX7 Camera Operation Unit
DXBK-701 SDI Output Board
RCP-TX7 Remote Control Panel
RMM-TXC7 Rack Mount Bracket
Design and specifications are subject to change
without notice.
1) Y/R–Y/B–Y, R/G/B, and Y/C outputs are switchable.
2) When the optional DXBK-701 is installed.
..........................................................................................................................................................................................................
20
Location and Function of Parts
Use and storage locations
Avoid using or storing the unit in the following places:
• Where it is subject to extremes of temperature
(operating temperature: 5
°
C to 40
°
C (41
°
F to
104
°
F)).
Note that in summer the temperature in a car with the
windows closed can reach 50
°
C (122
°
F).
• Very damp or dusty places.
• Where rain is likely to reach the unit.
• Places subject to severe vibration.
• Near strong magnetic fields
• Near transmitting stations generating strong radio
waves.
Avoid violent impacts
Dropping the unit, or otherwise imparting a violent
shock to it, is likely to cause it to malfunction.
Notes on Use
Do not cover with cloth
While the unit is in operation, do not cover it with a
cloth or other material. This can cause the temperature
to rise, leading to a malfunction.
After use
Turn the unit off.
Care
If the body of the unit is dirty, wipe it with a dry cloth.
For severe dirt, use a soft cloth steeped in a small
amount of neutral detergent, then wipe dry. Do not
use volatile solvents such as alcohol or thinners, as
these may damage the finish.