4-3-7. 22.5 MHz Carrier Level Adjustment
Equipment
:
Oscilloscope
To be extended :
YD-26 board
Test point
:
TP10 (GND: E5)/YD-26 board
Adjusting point :
1
RV7 (Y CARR LEVEL)/
YD-26 board
Specification
:
A = 400
±
20 mV p-p
(BW LIMIT/Oscilloscope
→
"OFF")