6
Electrical connection
6.1 Working on the electrical distributor
6.1.1 Placing components in the distributor
►
Place the following components in the electrical distributor:
1
2
3
KSW
1
2
3
KSW
T
2
A1 A2
N L1 L2 L3
power meter
WM 271
Strommessung
Erzeugung
Verbrauch
Current Measurement
Generation
Consumption
Voltage Metering
Spannungsmessung
3
4
5
1
Figure 18: Components to be placed in the distributor
1
Miniature circuit breaker | B10 – B16 (not included in scope of delivery)
2
Power meter
3
Transformer interface
4
B6 miniature circuit breaker
5
Residual current device (RCD) – 30 mA (not included in scope of delivery)
Explanations for the components:
•
The miniature circuit breaker (1) protects the connection line to the storage
system.
•
The power meter (2) and the transformer interfaces (3) are used to measure the
consumption and generation of power in the building.
•
The miniature circuit breaker (4) protects the line that is connected to the input
for measuring the voltage of the power meter (2).
•
The RCD (5) protects against high touch voltage in the event of a fault. In a TT
network you must fit a residual current operated device (5) upstream of the
storage system.
Page 34 of 115
KD-262 | Part-No 52199 | EN | Version 1.00
Summary of Contents for sonnenBatterie eco 7.0 Series
Page 7: ...Contents 17 Commissioning report 115 KD 262 Part No 52199 EN Version 1 00 Page 7 of 115...
Page 112: ...16 EU Declaration of Conformity Page 112 of 115 KD 262 Part No 52199 EN Version 1 00...
Page 113: ...EU Declaration of Conformity 16 KD 262 Part No 52199 EN Version 1 00 Page 113 of 115...
Page 114: ...sonnen GmbH Am Riedbach 1 D 87499 Wildpoldsried t 49 0 8304 92933 444 o info sonnenbatterie de...