12
Maintenance
12 Maintenance
For fault-free, safe, reliable and long-lasting operation of the storage system, it is
essential to carry out regular function checks and cleaning.
The battery modules installed in the storage system do not require maintenance.
12.1 Checking function
Table 3:
Checking function
Maintenance interval Action to be taken
Every 2 weeks
►
Check whether there is a fault with the storage system.
Every 6 months
►
Check for changes to the charging status.
If functioning properly, the storage system should be charged to 100% on a
sunny day and the charging status should drop significantly overnight.
12.2 Cleaning
Risk of material damage due to use of unsuitable cleaning agent an
excessive water
Unsuitable cleaning agents can scratch the surfaces. Furthermore, if cleaning is
not carried out properly, water can get inside the storage system and cause
damage. For this reason:
►
Do not use scouring cloths, sponges or cleaning agent.
►
Take particular care when cleaning the screen (if applicable) and the LED ring,
since these can easily be scratched.
►
Use only moist cloths, not wet cloths, to clean the system.
►
Do not use water jets.
►
Carefully clean the outside of the storage system with a clean, moist cloth.
For tougher dirt, use a small amount of household dishwashing detergent on a
moist cloth.
Page 100 of 115
KD-262 | Part-No 52199 | EN | Version 1.00
CAUTION
DANGER
WARNING
Notice
Summary of Contents for sonnenBatterie eco 7.0 Series
Page 7: ...Contents 17 Commissioning report 115 KD 262 Part No 52199 EN Version 1 00 Page 7 of 115...
Page 112: ...16 EU Declaration of Conformity Page 112 of 115 KD 262 Part No 52199 EN Version 1 00...
Page 113: ...EU Declaration of Conformity 16 KD 262 Part No 52199 EN Version 1 00 Page 113 of 115...
Page 114: ...sonnen GmbH Am Riedbach 1 D 87499 Wildpoldsried t 49 0 8304 92933 444 o info sonnenbatterie de...