User Manual for the Type 8300 Compatt 6
(and Variants)
UM-8300-Compatt 6
Issue B3
Figure 8–4 Removing the Guard and Bump Stop
Guard
Clamp Rings
Bump Stop
Nuts, Washers and Nylon Spacers
5. With the guard and bump stop removed, remove the clamp rings.
6. Remove any dirt, silt or water that may have accumulated around the endcap.
7. Using the Opening tools, lever the transducer endcap from the housing until the O-ring seals are
exposed; see
.
Figure 8–5 Removing Transducer Housing using the Opening Tools (Omni-Directional shown for
Reference)
Section 8 – Maintenance
40