User Manual for the Type 8300 Compatt 6
(and Variants)
UM-8300-Compatt 6
Issue B3
13.7 Communication Port
Type
RS232
Baud Rate (default)
Default 9600 baud (8 data bit, no parity, 1 bit stop)
Configurable to 2400, 4800, 9600, 19200, 38400, 57600 and 115200 baud
13.8 Acoustic
Transducer Type
MF
Omni-Directional
MF
Directional
LMF
Omni-Directional
LMF
Directional
Transducer Beam Shape
Hemispherical
(±80° @ 35 kHz)
Directional
(±25° @ 35 kHz)
Hemispherical
(±120° @ 18 kHz)
Directional
(±22° @ 18 kHz)
Frequency Range
MF 19–34 kHz
MF 19–34 kHz
LMF 14–19 kHz
LMF 14–19 kHz
Acoustic Sensitivity
(dB re 1 µPa)
<85
<85
<85
<85
Acoustic Transmit source level –
4 levels (dB re 1 µPa)
196/193/190/187
202/199/196/190 196/193/190/187
202/199/193/187
Pulse length, Wideband
(ms)
8/16
8/16
8/16
8/16
Time resolution (µs)
1
1
1
1
13.9 Environmental
Parameter
Specification
Temperature Operation
-5° to 40°C (23° to 104°F)
Temperature Storage
-20° to 55°C (-4° to 131°F)
Rated for Outdoor use
IP68
13.10 Sensors
Temperature Measurement
-5° to 40°C (23° to 104°F)
Resolution
0.01°C
Accuracy
±0.1°C (±0.05°C to special order)
Depth Measurement (Strain Gauge)
Span (depth)
5000 m
3000 m
1000 m
500 m
300 m
Resolution
0.01 kPa
0.01 kPa
0.01 kPa
0.01 kPa
0.01 kPa
Accuracy
±5.0 m
±3.0 m
±1.0 m
±0.5 m
±0.3 m
Depth Measurement (High Precision Strain Gauge)
Span (depth)
5000 m
3000 m
1000 m
500 m
300 m
Section 13 – Technical Specifications
91