12
Sensor allocation:
Wind sensor allocation is used to set which wind sensor the function should
listen to. The system can have two wind sensors connected and therefore the function can use
either one of them or both at the same time. You can allocate differently for each zone.
In “Wind unit” parameter you can change the representation of the wind value to m/s, km/s or
mph.
H
This function is active in both manual and automatic mode. For interior solar protection
this function is normally not used since interior solar protection is protected from wind by
the window. This function requires a wind sensor/s connected.
Wind parameters
Function
Range (Step)
Per Zone
Default
Advanced
Used
Yes/No
Yes
Yes
Yes
Threshold
5-20m/s
Yes
8m/s
No
On Delay
1-10s
Yes
3s
Yes
Off Delay
1-20min
Yes
10min
Yes
Unit
m/s, km/h, mph
No
m/s
Yes
Allocation
1 or 2 common, 1/zone
Yes
1/zone
Yes
Recommended MAX wind speed values for different solar protection
Type
Wind speed
On delay
Off delay
m/s
Km/h
Mph
Facade awning / Screen
10
36
20
3
10
External Venetian blind
15
54
33
3
10
Folding arm awning
8
18
18
3
10
H
For exact values please contact the solar protection supplier.
Precipitation – Rain and Snow
About:
The Precipitation function is used to protect the solar protection from rain and
snow. Doing so will prolong the life span of the solar protection, especially if they
are made of fabric.
Enable this function for each zone where you have external solar
protection by selecting Yes in the “Use function” parameter.
Active:
This function will get active
when the precipitation sensor signals rain or snow for a certain time (On delay). The solar
protection will be blocked in up position. The function will be inactivated after a certain time
(Off delay) as soon as the precipitation sensor stops to signal, hence the raining or snowing has
stopped .