10
/
Lock zone
Zone 1
Lock zone screen view
Lock zone- via control unit
About:
When this function is active the selected zone’s solar protection will be blocked
in up position. This function is often used during e.g. window cleaning. When this
functions is active the icon on the left side is shown on the main menu.
Active:
The function gets active by pushing the “Lock button”, (see page 5). For the 2 zones
version you’ll be asked which zone/s that should be locked (see picture above). Toggle to the
desired option with the navigation buttons (
S R
) and press (
ok
) when finished. Lock can be
active in both Manual and Automatic mode. Do the same as above to inactivate the function,
but this time choose the “none” alternative.
H
This function is always enabled.
Lock zone - via external switch
About:
This function is equal to “Lock - via control unit” except for that the function
is activated via a dedicated lock input, a potential free input (see
page 23.
). This
function will get active when the Lock input recieves a high signal. There is one Lock
input per zone.
Active:
Most often an external key switch is connected to the lock input. Insert the key and
switch. Pull out the key for safety reasons. Now the function will be active. Do the reverse to
inactivate the function.
H
Lock can be active in both Manual and Automatic mode. This function is always enabled.
Alarm
About:
When this function is active all solar protection will be blocked in up position.
The function is activated by an external potential free input (see
page 23
).
Active:
This function will get active when the Lock input gets low. In many cases the
buildings fire alarm is connected to this input to ensure that e.g. the blinds are not covering an
emergency exit in case of fire. In this case the Alarm function will get active when the building’s
fire alarm is active.
H
Alarm can be active in both manual and automatic mode. This function must be
enabled before it can go active. Alarm is enabled in the Settings menu.