30
d)
Fig. 39
– Installation of ventilation kit
Fig. 40
– 3 Position Switch
Attention:
all three wires in the power feed cable
– earth, neutral and live – should be
connected. We take no responsibility for any damage resulting from non-compliance with
this warning.
* The electrical components should always be connected to the power supply;
Position I –
Tangential fan automatically turns on
with an air flow of 60m3/h when the
thermostat reaches 50 °C.
Position 0 – Tangential fan keeps inactive.
Position II – Tangential fan is activated manually
with an air flow of 165m3/h.