13
Fig. 16– Fume outlet placed horizontally
4-
In the inner roof of the combustion chamber, unfasten the 6 screws using a socket
head hex wrench to release the fume outlet
;
5-
Reposition the fume outlet so that it spans horizontally through the external cover
across the section you cut off previously in the casing;
6-
Refasten the screws to the inner roof of the chamber to secure the fume outlet in the
horizontal position;
7-
Replace the fume baffle and top cover by following the steps above in reverse order;
8-
Use the additional cover provided (metal sheet for the Tek Basic model, and stone
cover for the Tek Stone model) to cover the section left open on the top of the unit
resulting from the repositioning of the fume outlet. For the Tek Stone models, you
must attach the additional support to the unit's external casing before using the
additional cover (Fig.17-[A]). Secure the support in position using the screws provided
(Fig.17-[B]).
Fig. 15 – Fume outlet retaining screws
[A]
[B]
Fig. 17– Attaching the cover support - TEK Stone model
Summary of Contents for TEK Basic
Page 6: ...6 Fig 2 Dimensions of the Tek Basic model Fig 3 Dimensions of the Tek Stone model ...
Page 7: ...7 Fig 4 Dimensions of the Tek Round model Fig 5 Dimensions of the Tek Unit model ...
Page 8: ...8 Fig 6 Dimensions of the Tek Roll model Fig 7 Dimensions of the Tek System model ...
Page 9: ...9 Fig 8 Dimensions of the Tek Corner model Fig 9 Dimensions of the Tek Wall model ...
Page 44: ...44 ...
Page 46: ...46 APPROVED PRODUCT ...