114
Alarm
Code
Troubleshooting
Pellet
drum
temperature
is
too high
Er01
110 °C, even with the
equipment OFF
- Room fan not working - call for
service
- Thermostat defective - call for
service
- Ventilation defective
Pressure regulator
alarm
Er02
Door open, draught
too
low or extractor fault
for
180 sec.
Only visible
if puller is set to ON.
- Close door and remove faulty
pressure switch
- Faulty exhaust pipe obstruction or
extractor
Extinguishing for
exhaust
under
temperature
Er03
Temperature
below
55ºC (Th03)
- Pellet reservoir is empty
- Faulty thermocouple
Extinguishing for
exhaust
over
temperature
Er05
Over 300 °C
- Room fan does not work or is at a
low power level - increase level to
maximum (if problem persists call
for service)
- Insufficient extraction
- Excess pellets
- Faulty smoke sensor
Encoder
fan
error: no Encoder
signal
Er07
No
rpm
signals.
Allows unlocking and
working by voltage in
a provisional way
P25=0
- Check connection
- Check that the fan is not blocked
- After remedying the fault, you
must select operating mode P25=2
again
Encoder
fan
error:
Combustion Fan
regulation failed
Er08
Encoder has signal
but failed regulation.
Can be released and
working temporarily
by voltage P25=0
- Blockage of exhaust pipe or
defective extractor
- After remedying the fault, you
must select operating mode P25=2
again
Failed ignition
Er12
Maximum time: 900 s
and
exhaust
temperature
below
50°C
- Empty auger channel - restarting
- Ignition resistance burnt out -
replace resistance
- Firing basket incorrectly placed
- Exhaust temperature did not
exceed the value set on activation
Summary of Contents for Everest
Page 138: ...133 ...
Page 139: ...134 ...
Page 140: ...135 ...
Page 141: ...136 26 Maintenance Guide Label ...
Page 142: ...137 Figure 126 Maintenance guide label 27 Electrical Diagram of the Free Standing Fire Unit ...
Page 154: ...149 Flow chart Nevada Flow chart 1 Lighting ...
Page 155: ...150 ...
Page 156: ...151 Flow chart 2 Disabling ...
Page 157: ...152 Flow chart Everest Flow chart 1 Lighting ...
Page 158: ...153 ...
Page 159: ...154 Flow chart 2 Disabling ...
Page 160: ...155 Flow chart Everest Round Flow chart 1 Lighting ...
Page 161: ...156 ...
Page 162: ...157 Flow chart 2 Disabling ...