respective chimney for the evacuation of fumes. These tasks should be carried out
every 600-800 kg of pellets consumed, in the case of stoves (air and water) and
compact boilers, and every 2000-3000 kg of pellets consumed in the case of automatic
boilers. In the event that these quantities are not consumed, at least one systematic
preventive maintenance must be carried out annually.
3.11
It is the Buyer's responsibility to ensure that periodic maintenance is carried
out, as indicated in the instruction and handling manuals accompanying the Product.
Whenever requested, it must be proved by submitting the technical report of the entity
responsible for it, or alternatively by registering them in the instruction manual in the
dedicated section.
3.12
In order to avoid damage to the equipment caused by overpressure, safety
elements such as pressure relief valves and / or thermal discharge valves, if applicable,
as well as an expansion vessel fitted to the installation, shall be ensured at the time of
installation and its correct functioning must be ensured. It should be noted that: the
valves referenced must have a value equal to or less than the pressure supported by
the equipment; there shall be no cut-off valve between the equipment and its safety
valve; provision should be made for a systematic preventive maintenance plan to attest
to the correct functioning of the said safety features; irrespective of the type of
appliance, all safety valves shall be channeled to drained sewage to prevent damage
to the dwelling by water discharges. Product Warranty does not include damages
caused by non-channeling of water discharged by said valve.
3.13
In order to avoid damage to the equipment and attached pipes by galvanic
corrosion, it is advisable to use dielectric separators in the connection of the equipment
to metal pipes whose characteristics of the materials applied to this type of corrosion.
Product Warranty does not include damages caused by non-use of such dielectric
separators.
3.14
The water or thermofluid used in the heating system (hydro stoves, boilers,
central heating stoves, among others) must comply with the legal requirements in
force, as well as guarantee the following physical and chemical characteristics: absence
of solid particles in suspension; low level of conductivity; residual hardness of 5 to 7
degrees; neutral pH, close to 7; low concentration of chlorides and iron; and absence
Summary of Contents for Everest
Page 138: ...133 ...
Page 139: ...134 ...
Page 140: ...135 ...
Page 141: ...136 26 Maintenance Guide Label ...
Page 142: ...137 Figure 126 Maintenance guide label 27 Electrical Diagram of the Free Standing Fire Unit ...
Page 154: ...149 Flow chart Nevada Flow chart 1 Lighting ...
Page 155: ...150 ...
Page 156: ...151 Flow chart 2 Disabling ...
Page 157: ...152 Flow chart Everest Flow chart 1 Lighting ...
Page 158: ...153 ...
Page 159: ...154 Flow chart 2 Disabling ...
Page 160: ...155 Flow chart Everest Round Flow chart 1 Lighting ...
Page 161: ...156 ...
Page 162: ...157 Flow chart 2 Disabling ...