14
Union of wall with a minimum of 13 cm internal diameter, then isolate the flue tube of
the machine with a suitable insulating material. (For example, 1,35 thickness with a
thermal conductivity of 0,07 W/m° K).
•
If installing the flue is next to a wall (less than 20 cm) where the condition
previously laid down the pipe must be isolated.
•
We recommend as an alternative to the use of insulated pipe insulation that should
be used overseas to avoid condensation.
Figure 9 - Minimum distances from a chimney to a heat-sensitive wall
•
IMPORTANT! In the installation of a flue pipe in the stove pellets, put the
output of the machine, a T-inspection with hermetic lid to allow regular inspection or
disposal of heavy dust and condensate.
•
As shown in Figure 10, the exhaust pipe must be held so that cleaning and
maintenance to be provided by the insertion of inspection points.
Minimum 20 cm heat-resistant wall