55
12.
Recommendations for the installation of the ductable air
(Nevada and Everest Round)
It is recommended that the installation of ductable air is carried out by an accredited
professional or installer in order to be properly sized.
The maximum length of the pipe is 7 m. The pipe must be resistant to temperatures
of at least 200ºC.
To take advantage of ventilation using ductable air, this unit must have an optional
ventilator installed
(See section 9 of this manual)
.
The installation requires a Ø100mm exit, so the unit must be adapted to have this type
of exit.
When installing the optional ventilator, check if the ductable air damper is in operation
While the unit is in operation, the user has the option to choose to extract “+” or “
-
”
ductable air into the room where the unit is installed or into a room where the ductable
air is directed to, by switching the damper's position.
Figure 86 – Adjusting the ductable air damper to “+” or “-”
Position “+”
Position “-”
“+” Ductable air
“+” Ductable air