41
Rev. 3
5.6 Cooling System
The genset cooling system is based on coolant circulation controlled by centrifugal pump with
thermostatic control and heat exchanger, where the coolant is refrigerated by sea water. Moreover, the
exhaust manifold is cooled also by sea water.
COOLANT CIRCUIT DESCRIPTION
Fig. 34. Coolant
circuit
Coolant Circuit Capacity (l)
8 GTC / 10 GTAC / 7 GSC / 8 GSAC
3,5
11 GTC / 14 GTAC / 10 GSC / 12 GSAC
6,25
17 GTC / 20 GTAC / 14 GSC / 17 GSAC
8,0
Table 13. Coolant circuit capacity
SEAWATER CIRCUIT DESCRIPTION
Fig. 35. Seawater circuit
COOLANT SPECIFICATIONS
It is recommended use KRAFFT ACU 2300 CC 50% coolant or another coolant with similar
specifications. On the other hand, distilled water with an anti-freezing agent is also suitable. The anti-
freezing agent concentration according to operating conditions is specified in anti-freezing agent
1.
Coolant pump
2.
Heat exchanger
3.
Thermostat
1.
Bottom cock (supplied as accessory)
2.
Sea water filter (supplied as
accessory)
3.
Sea water pump
4.
Heat exchanger
5.
Wet exhaust elbow
Summary of Contents for 10 GSC
Page 2: ...1 Rev 3...
Page 57: ...U_ 3002_EN Rev 2...
Page 58: ...1 Rev 2...
Page 71: ...14 4 1 5 History log...
Page 99: ...42...
Page 100: ...43 Rev 2 U_ 3002_EN Rev 2...
Page 101: ...7 2 Genset Dimensions...
Page 104: ......
Page 105: ...7 3 Alternator s Connections...
Page 106: ......
Page 107: ......
Page 108: ...7 4 Regulator s Connections...
Page 109: ......
Page 110: ......
Page 111: ...7 5 Electrical Wiring Drawings...
Page 116: ...7 6 Tightening Torques...
Page 118: ...7 7 Instructions for decommissioning scrapping and disposal...