Subject to changes | © 2020 SOLARWATT GmbH | AZ-TM-PME-1755 | Rev 000.2 | Version: 08/2020
Page 14
System confi guration
IMPORTANT
Before you start!
Always use the MyReserve string confi gurator for
system planning to confi rm the installation is suit-
able for the best operation of the battery system.
UK:
The confi gurator is available in the Expert Portal
(Pro) of our website www.solarwatt.com under the menu
item ‘Tools’.
AUS:
The confi gurator is available in the Professional
area of our website www.solarwatt.com.au under the
menu item ‘Tools’.
Installation
Requirements for the installation location
•
Installation in splash water protected outdoor areas
only if the installation steps for outdoor installation
have been followed
If the installation steps for outdoor installation have not
been followed, the following requirements apply:
•
Install the product in a cool, dry indoor space.
•
Maximum relative air humidity 85%. Do not expose
MyReserve to an environment that has higher air hu-
midity.
Generally, the following requirements must be observed:
•
Install the product either in a dry indoor space or a loca-
tion protected from any precipitation
•
Environmental temperature range for unlimited perfor-
mance is approx. 0°C to 30°C
•
Max. permissible environmental temperature range is
approx. -15°C to 45°C.
•
Do not expose the product to direct sunlight.
•
Do not install MyReserve in emergency escape routes
or bedrooms
•
MyReserve must not block access to switching devices
in the installation location.
•
Install the product so that it is not accessible to chil-
dren, mentally disabled persons or animals.
•
The installation location must be chosen so that the
product cannot be exposed to any type of fl ooding.
This is assured with a suffi cient installation height (min-
imum 30 cm from the fl oor) and a suitable drain-free or
water-supply-free installation location.
•
Do not store any fl ammable or explosive materials in
the installation room.
•
Installation in heater rooms (defi ned as heating sys-
tems for solid fuels with a total rated output of more
than 50kW that may not be used for any other purpos-
es), oil or wood storage facilities, wooden barns and
sheds, etc. is not permitted.
•
Do not use MyReserve in vehicles (motor vehicles, air-
craft or ships)
•
Do not use MyReserve in areas which are prone to ex-
plosion (fl our dust, saw dust, etc.)
•
Do not install MyReserve at locations over 2000m
above sea level
•
Do not install MyReserve in atmospheres that are cor-
rosive or contain alkali and do not store corrosive or
fl ammable materials in its vicinity
•
Do not install MyReserve in environments with mois-
ture / atmospheres having a high salt content, near heat
sources or in areas at risk of fi re
•
The wall and fastening material must be able to bear
a static load corresponding to the specifi ed product
weight.
•
Do not place the MyReserve above or below other
equipment.
•
Keep it away from direct heat emitted by other equip-
ment, and maintain the minimum safe distances to
other devices specifi ed by the manufacturers of those
devices.