Establishing CAN communication between MyReserve Command and AC Sensor
NOTE
Always use a twisted wire pair of a network cable (minimum Cat.5e) for CAN H and CAN L. This improves
shielding from interfering infl uences. The maximum possible cable length for the CAN connection is 100m.
DO NOT run the CAN cable in the same conduit as the AC cabling.
NOTE
NOTE
NOTE
•
establish CAN communication between MyReserve Command and AC sensor via patch cable
IMPORTANT
If you use a network installation cable, the corresponding RJ45 connectors are available in the SOLARWATT web-
shop (DELOCK 86287 RJ45 connectors).
Make sure that the pins H (pin 1), L (pin 2) and GROUND (pin 6) are connected to MyReserve Command and the
AC sensor with the same assignment.
NOTE
When using the MyReserve Backup Power from SOLARWATT, the CAN connection is made via all pins. In any
case, please refer to the wiring diagram in the MyReserve Backup Power Installation Instructions.
NOTE
NOTE
NOTE
Fixing installation cables
•
attach two cable ties (included in delivery) on the
lowest wall bracket
•
Fix the installation cables with the cable ties