WireXpert User Interface
26
© Copyright 2019 Softing IT Networks
•
AC Wire map – If enabled, WireXpert is able to measure test runs with
Power over Ethernet (PoE) midspan devices in between. The
WireXpert supports cable runs with IEEE 802.3 af and 802.3 at
injectors. Disabled by default. Option will be disabled when Shield
Test option is enabled.
•
Crossover – If enabled, depending on the limits selected, WireXpert is
able to test one or more of the follow crossover cable. Disabled by
default.
Straight-through
cable
Crossover at pairs
12, 36
Crossover at pairs
12, 36, 54, 78
Crossover at pairs
12, 36 and reversed
at pairs 54, 78
Crossover at pairs
12, 36 for 2-pair
cable
•
DCRU – If enabled, WireXpert will perform additional DC resistance
unbalance test measurements between and within each pair in
accordance with TIA and IEC specifications, on top of the AUTOTEST
parameters required in a Channel or Permanent Link. Disabled by
default. Option is only available with CAT6A+ adapters.
•
Shield Test – If enabled, WireXpert will perform shield integrity test to
identify if a shield is present and connected between both ends on
the actual cable under test. Disabled by default. Option is only