
Performing an AUTOTEST
48
© Copyright 2019 Softing IT Networks
Locator – To enable, press the
[SETUP]
button
Test
Settings
Test Options
Locator
NEXT Locator
Return Loss Locator
7.3
Managing test result(s)
Test results can be manually saved by pressing the
[Save]
button after an AUTOTEST is completed.
When prompted, enter label name and click
[OK]
to save.
The
[Save]
icon will disappear
once saving is completed.
Test results will be named in alpha-numeric sequence with reference to the selected Label Source
(
[SETUP]
Project Settings
Label Source
) when AUTOTEST is completed.
PASS results will automatically be saved if the “Auto Save” option is enabled. FAILED results will be
saved manually.